WIRING DIAGRAM OF THE READERS
3
∅ 9/10 diameter
from 2 to100 M
Reader
Reader
2 wires
Max
D+ D-
20 cm
Amplif.
D-
Signal
D
+
NC
Flat Reader
2 Wires
AV0151/013
Noise
Rec. OK
Short-circuit the terminal pins B+ and B- if not used
- The Vigik reader must be 2 meters away from the controller.
- Each reader must be connected to the controller by a dedicated wire line.
- The dedicated wires must be 20cm away from the power supply.
- The operating temperature ranges between -20°C to +70°C.
Proximan is always checking its connections with the proximity readers. The autodiagnosis will be displayed
on the controller.
8
Door Wiring
Door
Lock
command
2 x 0.50 mm
max 100 m
Exit push button
contact NO
Door Wiring
Door
L+ L-
BP+ BP-
COM NF
NO
lock
Door Wiring
Door
L+ L-
BP+ BP-
COM NF
NO
lock
WIRING OF DOOR LOCK
4
COMMAND OF ANY LOAD
If it is needed an open or closed contact, connect the load in the following way:
DRY CONTACT: NORMALLY OPEN
DRY CONTACT: NORMALLY CLOSED
2
ELECTRICAL LOCK (NORMAL)
To open the door, the power supply is provided by closing the contact:
- In case of alternative current, use a varistor instead of a diode
- It is recommended not to use the same power supply for the locks and the controller.
MAGNETIC OR BREAKING COMMAND FOR DOOR LOCK RELEASE
To open the door, the power supply is interrupted by opening the contact:
- It is recommended not to use the same power supply for the locks and the controller.
It is compulsory to install the protecting diode. No indication on the lock can exempt you from
doing so. The diode's type is usually 1N4004 or 1N4007.
DS90355-015
DS90355-015
CONTROLLER
COM
LOAD
NO
CONTROLLER
COM
LOAD
NF
CONTROLLER
12Vdc
+
-
COM
Protecting
LOCK
diode
NF
CONTROLLER
12Vdc
+
-
COM
Protecting
LOCK
diode
NF
9