Pumpable Liquids; Technical Data And Limitations Of Use; Management; Storage - Tallas D-EBOOST 850/45 Instructions Pour L'installation Et La Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
These pumps cannot be used in swimming pools, ponds or basins where people are present, or for
pumping hydrocarbons (petrol, diesel fuel, combustible oils, solvents, etc.) in accordance with the
accident-prevention regulations in force. They should be cleaned before putting them away. See the
chapter "Maintenance and Cleaning".

2. PUMPABLE LIQUIDS

Clean, free from solid bodies or abrasive substances, non-aggressive.
Fresh water
Rainwater
(filtered)
Clear waste water
Dirty water
Fountain water (filtered)
River or lake water (filtered)
Drinking water
Suitable
Not suitable
o

3. TECHNICAL DATA AND LIMITATIONS OF USE

Supply voltage: 220-240V, see electrical data plate
Delayed line fuses (220-240V version): indicative
values (Ampere)
Storage temperature: -10°C +40°C
Electrical
P1 Rated absorbed power [W]
data
P2 [W]
Mains voltage [V]
Mains frequency [Hz]
Current [A]
Capacitor [µF]
Capacitor [Vc]
Hydraulic
Max. flow rate [l/h]
data
Max. head [m]
Max. head [bar]
Max. pressure [bar]
Max suction depth [m/min]
Range of
Length of power cable [m]
use
Type of cable
Grade of motor protection
Insulation class
Liquid temperature range [°C]
EN 60335-2-41 for domestic use
Max. particle dimension [mm]
Max. ambient temperature [°C]
Weight
DNM GAS
Net/Gross weight approx. [kg]
The pump cannot support the weight of the pipes, which must be supported in some other way.

4. MANAGEMENT

4.1

Storage

All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.
4.2

Transport

Avoid subjecting the products to needless impacts and collisions.
4.3

Weight and dimensions

The adhesive plate on the packaging indicates the total weight of the pump and its dimensions.
ENGLISH
Model
according to
Table 3
o
o
Table1
Model
P1= 850
P1= 1100
P1= 640
P1= 920
P1=850
P1=1100
850
1100
600
750
3.88
4.58
12.5
16
3180
3750
43
45
4.3
4.5
8m / <3min
9.6/11.8
10.3/12.5
2
Line fuses
220-240V 50Hz
4
6
4
6
P1=640
640
380
1~220-240 AC
50
3.10
16
450
3600
32
3.2
6
6m / < 3min
1.5
H07 RNF
IPX4
F
0°C / +35°C
Clean water
+40°C
1'' M
10.1/12.1
Table2
P1=920
920
560
4.20
12.5
4800
40
4.0
10.9/12.9

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

D-emulti 1000/40D-emulti 1000/45P1-850P1-1100P1-640P1-920

Table des Matières