9.2. Air Gun

Problem
Gun does not ionize or ion-
izes insufficiently
No compressed air from
the gun
Insufficient compressed air Compressed air pressure
Valve remains stuck
table 2 faults

10. Repair

Warning:
 When carrying out work on the equipment: de-energise the equipment.
 Repairs shall be made by a skilled engineer.

10.1. Cobra Air Gun

Damaged HV cables may be shortened.
1. Cut off the cable at the damaged spot.
2. Strip the HV cable sheath 40 mm off.
3. Strip the cores 6 mm off.
4. Provide the cores with M3 cable lug.
To order parts, see the spare parts list.

10.2. Power Unit

It is not possible to repair parts of the power unit. To order parts, see the spare parts list.
If the equipment is in need of repair, you may send it to SIMCO (Nederland) B.V.
Request an RMA form by sending an e-mail to service
Pack the equipment properly and clearly state the reason for return.
Cobra_UM_9752050610_NL_D_GB_F_V2_0
Cause
Power unit not switched on Switch on power unit
Power unit is defective
HV cable interrupted
Ionizing part is defective
Compressed air hose not
connected
Valve is defective
set too low
Valve is subject to exces-
sive resistance when being
activated
Remedy
See power unit manual
If possible, shorten HV ca-
ble or return air gun for
repair
Return air gun for repair
Connect compressed air
hose
Replace the valve
Correctly set the com-
pressed air pressure
Lubricate valve spindle