Functional Description
LK 110, LK 120 and LK 130 SmartComfort are electronic tempe-
rature controllers for hydronic radiator and underfl oor heating
applications. All models are equipped with frost protection and
minimum/maximum limitation of the supply temperature.
LK 110 and LK 130 are equipped with an outdoor sensor. The supply
temperature is adjusted according to the outdoor temperature.
Technical Data
Protection class........................................................................ III SELV (EN 60730-1) (double insulated)
Surrounding temperature, actuator and room controller 0 to +50°C, +32°F to +122°F
Air humidity............................................................................. <90% Rh, without condensation
Enclosure class, actuator........................................................ IP 40 (according to EN 60529)
Enclosure class, room controller.......................................... IP 20 (according to EN 60529)
Enclosure class, outdoor sensor........................................... IP 66 (according to EN 60529)
Enclosure class, AC adapter................................................. IP 20 (according to EN 60529)
Primary voltage, AC adapter............................................... 100 - 240 VAC, 50/60 Hz
Connector, AC adapter.......................................................... Europlug CEE 7-6 or USA: NEMA 1-15
Angle of rotation / Actuator direction............................... 90°/clockwise and counterclockwise
Actuator torque....................................................................... 5 Nm
Room temperature, setting range (LK 120 & LK 130)... +5°C to +37°C, +41°F to +99°F
Operating modes (LK 120 & LK 130)................................. Comfort/Reduced/Automatic/
Clock (LK 120 & LK 130)....................................................... 12 hrs. AM/PM and 24 hrs. Running
Manual operation................................................................... Yes, when needed
Indoor temperature range (LK 120 & LK 130)................. 0°C to +50°C, 32°F to +122°F
Outdoor temperature range (LK 110 & LK 130).............. -50°C to +50°C, -58°F to +122°F
Water supply temperature setting...................................... +5°C to 99°C, +41°F to 210°F
Regulating curve, setting (LK 110 & LK 130)................... 1.0 - 9.9
Parallel shift of regulating curve (LK 110 & LK 130)...... +-10°C, +-18°F
Min. fl ow temperature (LK 110, LK 120 & LK 130)........ +5°C to +40°C, +41°F to 104°F
Max. fl ow temperature (LK 110, LK 120 & LK 130)....... +20°C to +99°C, +68°F to 210°F
Dimensions, actuator............................................................. Length x width x height 93 x 80 x 75 mm
Dimensions, room controller................................................ Width x height x thickness
Dimensions, AC Adapter...................................................... Length x width x height 74x 30 x 43 mm
Installation

Installing the Actuator:

Rotate the axle on the mixing valve A counterclockwise and re-
1.
move the knob without changing the position of the axle.
Screw the fi xation bolt B in a suitable hole on the mixing valve
2.
A. Remove any existing bolt. Push the adapter C on the mixing
valve axle so that the axle bottoms in the hole. The supplied
adapter C suits most valve axles. Other versions of this adapter
are available as accessories. Please contact LK Armatur AB for
more information.
Fit the actuator D to the adapter C. The bolt B should fi t in the
3.
intended hole on the actuator.
Fit the knob E so that the indicator points to the counterclock-
4.
wise end position. Tighten the knob with the washer and the
bolt F.
Use a screwdriver to turn the disengaging button G to the posi-
5.
tion with hand symbol
E from one end position to the other. It is important that the
motor can be turned the whole turning angle (90°).
Turn the decoupling screw G back to the Automatik position
6.
4
or UK: BS 1363
Holiday/ Timer
reserve 24 hrs.
. Turn the valve with the knob
LK 120 and LK 130 are provided with a room controller. The
controller can be set to the desired room temperature. To
save energy, there are programmes that have scheduled tem-
perature changes.
LK 130 is equipped with an outdoor sensor, a supply sensor and
a room controller to optimize the control of the heating system.
A
B
C
.
Delivery Check
Check that the delivery, depending
on model, includes the components
listed below.
110 120 130
Actuator
Mounting kit (Fixation
bolt, fi xing screw, lock-
washer, adapter)
Knob with indicator
Room controller
with 15 m cable or
with antenna
Outdoor sensor
with 15 m cable
Water supply sensor
with 1 m cable
AC adapter 100-240
VAC, 50/60 Hz with
1.8 m cable
Cable ties