Function and features
The AS-i module operates as a slave in the AS-i network (AS-i profile:
S 7.0). It connects four sensors (2-wire sensors or pnp 3-wire sensors,
18 ... 30 V DC) and four actuators (10 ... 30 V DC) with the AS-i master.
• max. number of modules per master: 31
• Watchdog function: if the connection to the master is interrupted
for more than 40ms, the 4 outputs are disconnected
• total current consumption from the AS-i network: < 240 mA
• max. current load per output (DC13)* 1 A per channel, 4 A per
module
• sensor-/ actuator connection via screw terminals / Combicon
*
Utilisation category (DC13): The switch-on and switch-off capacity for the triggering of solenoids is rated up
to 20 W (to IEC 947-5-2).
Mounting
Mount the module onto a 35 mm rail or fasten it onto a mounting
device.
Ensure a suitable heat dissipation (enable air circulation). Mount the
module in a vertical position if possible.