Replacing Battery (continued)
5. Disconnect the battery:
• For F6C700 -EUR (700VA) and F6C1000 -EUR (1000VA) models,
disconnect the batteries and UPS by loosening the connectors.
• For F6C1400 -EUR (1400VA) model, disconnect the batteries
and UPS by pulling apart the two white couplers that are
connected together.
6. Connect the new battery:
• For 700VA and 1000VA models, connect positive (+) connectors
(RED-RED) and negative (-) connectors (BLACK-BLACK) together.
• For 1400VA model, connect the two white connected couplers on
battery and UPS together.
Red (+)
Red (+)
7. Re-assemble the UPS as shown above.
8. For environmental protection, do not dispose old batteries anywhere.
Contact your battery supplier for proper recycling of old batteries.