 Clean the quartz glass. If you are replacing the quartz glass:
– Undo the clamping screw and carefully pull off the quartz glass with a slight tilting and
twisting movement.
– Clean the O-ring, replace it if it is damaged.
– Grease the O-ring with OASE grease (order number 27872) and pull it over the rim of the
quartz glass to avoid grease residue on the quartz glass.
– Position the quartz glass on the rotor cover and turn the clamping screw up to the stop,
otherwise it is not possible to install the rotor cover.
 Check the profile wear on the cleaning rotor. (→ Replacing the cleaning rotor)
 When installing the quartz glass, turn the rotor cover up to the stop (bayonet lock to "lock
closed"). Otherwise you cannot install the UVC unit head.
Condensate may form in the quartz glass. This condensate formation cannot be avoided,
however, it does not impair function and safety.