Assembly Instructions

The appliance must be fully assembled before use! We
recommend that you refer to the figures „Overview of the
Components" and „Assembly overview" when assembling.

Base Unit (Fig. a - c)

1. Screw the tubes (7) onto the stand (13). Use the four
screws (12), the metal plate (14), and the four nuts (15).
2. Attach the cover of the stand (16) to the stand tubes.
NOTE:
The nuts and screws (17) are preinstalled on the rear
of the switch housing.
3. Check if the screws (17) possibly have been screwed
into deeply. In this case, turn the screws back a little. Do
not screw them out all the way!
NOTE:
If a screw or a bolt should have dropped off, proceed
as follows:
• Hold the preassembled unit (motor (18), switch
housing (6), and humidifier base (10)) so that the
motor points down.
• Insert one nut (M6) each into the shaft at the side
of the recesses for the tubes.
• Screw the two screws (17) on the rear of the switch
housing lightly into the nuts.
4. Set the preassembled unit for a depth of approximately
3 cm onto the stand tubes.
NOTE:
The humidifier cable must be routed between the two
tubes.
Secure the preassembled unit to the stand tubes by
tightening the two screws (17).
5. Fasten the base of the humidifier (10)
with the large screw (ST4*25 mm) to
the base of the stand. For this, insert
the screw from below through the
stand and its cover into the small outer
bore (Fig. on the right).

Fan (Abb. d)

6. Remove the preinstalled nut (20) from the motor (18).
Keep it close to hand.
7. Align the rear protection grid (19) with the motor
recesses (18).
NOTE:
The handle must point upwards.
8. Tighten the nut (20) for the rear protection grid clock-
wise.
9. Attach the propeller (3). When doing so, use the guide
pin on the motor shaft.
10. Tighten the screw (21) for the propeller anti-clockwise.
PC-VL3069LB_IM
11. Remove the prefitted screw and nut (5) from the front
protection grid (22). Keep it close to hand.
12. Open the fastening hooks (2) at the front protection grid.
13. Attach the front protection grid by engaging the groove
of the hook (1) with the rear protection grid.
NOTE:
The holes for the screw (5) in the front and rear pro-
tection grid must be aligned.
14. Secure the protection grid with the screw and the nut (5).
15. Close the four fastening hooks (2).

Humidifier (Fig. e - f)

The tube already may have been installed on the switch
housing. In this case, continue the assembly from item 18.
16. Feed the tube (8) from front to back between the two
stand tubes (7). Then insert the tube from the bottom
upwards through the opening on the underside of the
switch housing (6).
NOTE:
The end of the tube with the tank cap must be posi-
tioned at the front above the humidifier.
17. Insert the tube from the back to the front through the
opening on the top of the switch housing.
18. Pull the tube tight so that it lies flat against the back of
the switch housing.
NOTE:
The two ends of the tube should have approximately
the same length.
19. Connect the top end of the tube to the tube connector on
the protection grid (22).
NOTE:
The tube above the switch housing must not "sag".
Water which accumulates in the tube prevents the
formation of the mist. If necessary, push back the top
section of the tube.
20. Place the water tank (9) onto the base of the humidifier
(10).
21. Fit the tank cap on the bottom end of the tube onto the
water tank. The recess on the tank cap must fit into the
groove on the opening to the water tank.
NOTE:
• The tank cap on the end of the tube can be turned.
• The water tank must be fitted securely to the base
so that mist cannot escape between the water tank
and the base. If necessary tighten the lower section
of the tube.