Advanced Networking Application With Bms Integration; Display Messages - Leviton Luma-Net LumaCAN NP00G Manuel De L'utilisateur

Masquer les pouces Voir aussi pour Luma-Net LumaCAN NP00G:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.3 ADVANCED NETWORKING APPLICATION WITH BMS INTEGRATION

Ethernet
Luma Graphics
Luma Scheduler
Power
SectorNet
Luma-Net
LumaCAN
Note: LumaCAN Gateway used with GreenMAX only may use bacnet/IP direct to GreenMAX Cabinet

8. DISPLAY MESSAGES

1.
Bootloader XX.YY - bootloader application is running, XX.YY indicates the application version.
2.
Reading File - reading the programming file from the SD card.
3.
Checking File - validating file against flash.
4.
Interactive - waiting for commands from the serial terminal.
5.
Rebooting - rebooting device.
6.
Launch App - starting application.
7.
Burn Internal - reprogramming application.
8.
Erase External - reprogramming application.
9.
Burn External - reprogramming application.
10. Init Hardware - initializing hardware.
11. Init File System - initializing file system.
12. Init Ethernet - initializing Ethernet.
13. Waiting for DHCP - waiting for DHCP to give an address.
14. Configuring - configuring subsystems.
15. Ready - startup sequence complete.
16. Start Fail - the startup configuration script could not be read from the SD card.
17. LN:xxx CAN:yyy - Luma-Net
18. No Config - no configuration stored.
19. WatchdogTimeout SSSS - subsystem SSSS failed where SSSS is a name.
20. Factory Defaults Total Clear - a "Total Clear" press sequence was detected and executed.
21. Factory Defaults Configuration - a "Configuration Clear" press sequence was detected and executed.
22. Rebooting...5 - will reboot in 5 seconds (Continues to count down until it reaches 1 Second).
23. Boot Failed...Retrying - this is the result of the device not completing the startup sequence after ten minutes.
+24vdc
Luma-Net
NPDLR-000
LUMA-NET 3
SAPPHIRE-NET
COLORNET
T
R
DMX
DMX
OUT
IN
DMX512 OUT
DMX512 IN
ACTIVE
ACTIVE
10/100
RS 232
NPCDLR
a-2000
R
TM
TUALATIN, OR
MADE IN U.S.A.
INDUSTRIAL CONTROL EQUIPMENT
LISTED
32300A
R
88H9
C
R
+Vac
(LN) and LumaCAN
®
Page 10
+24vac
Luma-Net
Power Supply
LumaCAN®
B
Power
Ethernet Luma-Net®
MS/TP
A
Expansion
Link/RX
Error
Reset
TX
Network Protocol Converter
NP00G
LumaCAN
Gateway
BACnet/IP
R
BRIGHT
FULL
PHASE LOSS
FULL BRIGHT
FAN
SELECT
COMMUNICATION PORTS
SAVE
DMX
AUXILIARY
CANCEL
LUMANET
CLEAR
PHASE
A
CONTROL
PHASE
B
C
PHASE
NORMAL
BYPASS
MODULE
1
MODULE
2
MODULE
3
NORMAL
BYPASS
MODULE
4
MODULE
5
MODULE
6
NORMAL
BYPASS
MODULE
7
MODULE
8
Sector Ballast
MODULE
9
NORMAL
BYPASS
MODULE
10
MODULE
11
Line
MODULE
12
Voltage
A2000
(CAN) address.
TM
GreenMax
LumaCAN
Cabinet
+Vac
SectorNet
+Vac
Sector
Bus Controller

Publicité

Table des Matières
loading

Produits Connexes pour Leviton Luma-Net LumaCAN NP00G

Table des Matières