This will require two strong people –do not
attempt this step on your own. Bracket "B"
has slots, position C per Diagram "A" (refer
to page 5), at the top that will receive the
spring clips located on Bracket "A" - THIS
IS A TEMPORARY HOLD ONLY - DO
NOT RELY SOLELY ON THESE CLIPS
TO HOLD THE HOOD UP - THEY WON'T.
Once "hooked" by the spring clips immedia-
tely secure the structure with the machine
screws at point "E" on the schematic on
page 5 - this must be done immediately
and should not be skipped.
Ensure the entire structure is sturdy- serious
injury, death and MAJOR damage could re-
sult should the unit not be well connected to
the frame structure within the ceiling.
This is of utmost importance – do not go any
further until this has been tested and double
checked – the installer has sole responsibi-
lity for the safe installation of this product.
Once the entire structure has been fixed to
the ceiling slide the chimneys on the assem-
bled structure from the bottom up as per the
schematic on page 5. And fix the chimneys
with the screws supplied. Raise the upper
chimney to the ceiling and fix it to the bra-
cket "A" with the screws supplied "D".
Connecting Electricity and Ducting.
Make sure power is turned off at the source.
Make the electrical connection (see figure
2). Test the functioning of the hood. Slide the
upper chimney into place and attach with
the machine screws provided to Bracket "A".
fig. 2
Re-Circulating Requirements.
Fit the carbon filter after the installation is
complete – these fit in behind the aluminum
grease filter.
A short length of ductwork must be connec-
ted from the exhaust outlet up to the deflector
(must be purchased with hood).
The deflector, after attaching part B with
screws E connects to the top of Bracket "A"
and forces the air out through the grills on
the side of the chimney section back into the
room. (see diagram C).
8