Technical Data
Soldering iron
Temperature range °C
Temperature range °F
Power consumption
Voltage
Heat-up time
(50°C to 350°C) (120°F to 660°F)
Tip type series
Supply unit
Desoldering tweezers /
Desoldering iron
Temperature range °C
Temperature range °F
Power consumption
Voltage
Heat-up time
(50°C to 350°C) (120°F to 660°F)
Tip type series
Supply unit
Symbols
Caution!
Read the operating instructions!
Soldering
Desoldering
Hot air
Warranty
Claims by the buyer for physical defects are time-barred
after a period of one year from delivery to the buyer. This
does not apply to claims by the buyer for indemnification
in accordance with §§ 478, 479 BGB (German Federal
Law Gazette).
We shall only be liable for claims arising from a warranty
furnished by us if the quality or durability warranty has
been furnished by use in writing and using the term
WXP 65
WXP 80
100°C - 450°C
100°C - 450°C
212°F- 850°F
212°F- 850°F
65 W
80 W
24 V / AC
24 V / AC
7 s
10 s
XNT
LT
WXMT
100°C - 450°C
212°F- 850°F
80 W
(2x40 W)
12 V / AC
3 s
RTW
WX / WXD / WXA / WXR
WXP 120
WXP 200
100°C - 450°C
100°C - 450°C
212°F- 850°F
212°F- 850°F
120 W
24 V / AC
24 V / AC
10 s
XT
WX / WXD / WXA / WXR
WXDP 120 /
WXDP 120 Robust
100°C-450°C
212°F-850°F
120 W
24 V / AC
35 s
XDS
WXD / WXR
Disposal
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2012/19/EU on waste
electrical and electronic equipment and its
implementation in accordance with national law,
electric tools that have reached the end of their
life must be collected separately and returned to
an environmentally compatible recycling facility.
Dispose of replaced equipment parts, filters or
old devices in accordance with the rules and re-
gulations applicable in your country.
CE mark of conformity
„Warranty".
The warranty shall be void if damage is due to improper
use and if the device has been tampered with by unau-
thorised persons.
Subject to technical alterations and amendments.
For more information please visit
www.weller-tools.com.
WXMP
100°C - 450°C
212°F- 850°F
200 W
40 W
(RT11: 55 W)
12 V / AC
25 s
3 s
XHT
RT
WXDV 120
100°C-450°C
212°F-850°F
120 W
24 V / AC
35 s
XDS
27