Télécharger Imprimer la page

ENERMAX MAXREVO Manuel D'utilisateur page 4

Publicité

ENERMAX MAXREVO Series Power Supply Specification
AC Input Voltage
AC Input Current
Rated
3.3V
0-25A
5V
0-25A
12V1
0-30A
12V2
0-30A
12V3
0-30A
12V4
0-30A
12V5
0-30A
12V6
0-30A
-12V
0-0.5A
5Vsb
0-4A
Total Power
Peak Power
Over Current
Protection
(DC)
Under Voltage /
Over Voltage
Protection
(AC)
Under Voltage
Activated when AC input voltage < 70VAC.
Protection
Over Power
Activated when output power > 110 ~160% of rated max load.
Protection
Over
Temperature
Activated when PSU heat sink > 90 ~ 110
Protection
Short Circuit
Activated when any DC rails short-circuited.
Protection
Surge & Inrush
Sustain 2KV surge stroke.
Protection
Sustain up to 70A inrush current @ 240VAC at cold start.
Operation ambient: 0~50
Temperature
Storage ambient: -40~70
Operation: to 85% relative humidity, non-condensing at 25
Humidity
Storage: to 95% relative humidity, non-condensing at 50
> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25
MTBF
(MIL-HDBK-217F standard)
Dimension
150 (w) x 86 (h) x 180 (d) mm
2.25kg (without modular cables) ±50g
Weight
Safety
UL/cUL(Level 6), TUV, CCC, GOST, CB, BSMI (1200/1350W)
EMC
CE, FCC, KCC
EMR1200EWT
115-240VAC, 50-60Hz
(Maximum range: 100-264VAC, 47-63Hz)
12.5– 5.5A
DC Output
Combined
140W
1200W
(100A)
6W
20W
1200W
1440W
Protection Circuit
DC Rail
3.3V
5V
12V1/2/3/4/5/6
DC Rail
3.3V
5V
12V1/2/3/4/5/6
-12V
ENVIRONMENT
o
C (for full rated output)
o
C
OTHERS
EMR1350EWT
14.5 – 6.5A
Rated
Combined
0-25A
140W
0-25A
0-30A
0-30A
0-30A
1344W
0-30A
(112A)
0-30A
0-30A
0-0.5A
6W
0-4A
20W
1350W
1620W
OCP trigger range
30 – 45A
30 – 45A
40 – 50A
UVP trigger range
2.0 – 2.4V
3.3 – 3.7V
8.5 – 9.5V
-8.5 – -9.5V
o
C.
o
C
2
EMR1500EGT
220-240VAC, 50-60Hz
8.0 – 7.0A
Rated
Combined
0-25A
140W
0-25A
0-30A
0-30A
0-30A
1500W
0-30A
(125A)
0-30A
0-30A
0-0.5A
6W
0-4A
20W
1500W
1650W
OVP trigger range
3.9 – 4.5V
5.7 – 6.5V
13.3 – 14.5V
-13.3 – -14.5V
o
C
o
C

Publicité