Installation
Install the device in a well-ventilated area. The operation in an unsufficiently ventilated room can lead to a
condensation of the smoke fluid. The resulting slippery surface can cause accidents. Keep a minimum
distance of 20 cm around and above the device.
Furthermore do not orientate the escape nozzle directly in the direction of the audience's eyes. In order to
create a good effect, there should be a distance between the device and the audience of at least 1.5 m.
Only install the smoke-machine on scratch resistant and water resistant surfaces.
This device is only constructed for a standing installation.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
OPERATION
Switch the device on via the power switch. The red LED on the device as well as that of the remote control
lights up.
After a certain warm-up time, about 5 minutes, the green LED on the device as well as that of the remote
control turns on and the device is ready to operate.
Then you may choose between manual control mode or DMX control mode.
Manual Control Mode
For Manual Control Mode, all dip switches must be set on OFF.
International
L
N
Timer ON/OFF with lock:
To engage the timer function, depress the yellow
TIMER ON/OFF button, the yellow LED turns on, and
adjust the three knobs. The INTERVAL knob
regulates the length of time between each fog blast.
The blast can be set for between 6 and 200 seconds.
The DURATION knob controls the duration of each
fog emission. This can be set between 6 and 200
seconds. The VOLUME knob controls the emission
volume during Timer and Continue. To quit the Timer
function, press the yellow Timer button again. The
yellow LED turns off.
Continue ON/OFF with lock:
To engage the continue function, depress the red
CONTINUE ON/OFF button and regulate the
emission volume by adjusting the VOLUME knob.
The continue function will emit fog until the red
CONTINUE button is depressed again.
17/38
51701982_V_1_0.DOC