Télécharger Imprimer la page

PLYMOVENT FAN-42 Manuel Opérateur page 5

Publicité

Les langues disponibles

Les langues disponibles

1
SAFETY INSTRUCTIONS AND
Nederlands
WARNINGS
General
The manufacturer does not accept any liability for
damage to the product or personal injury caused by non-
observance of the safety instructions in this manual, or
by negligence during installation, use, maintenance and
repair of the product mentioned on the cover of this
document and any corresponding accessories.
Specific working conditions or used accessories may
require additional safety instructions. Immediately
contact your supplier if you detect a potential danger
when using the product.
The user of the product is always fully
responsible for observing the local safety
instructions and regulations.
Observe all applicable safety instructions and
regulations.
User manual
Everyone working on or with the product, must be
familiar with the contents of this manual and must
strictly observe the instructions therein. The
management should instruct the personnel in
accordance with the manual and observe all
instructions and directions given.
Never change the order of the steps to perform.
Always keep the manual with the product.
1
Intended use
The product has been designed exclusively for extracting
harmful fumes and gases which are released during the
most common welding processes. Using the product for
other purposes is considered contrary to its intended
use. The manufacturer accepts no liability for any
damage or injury resulting from such use. The product
has been built in accordance with state-of-the-art
standards and recognised safety regulations. Only use
the product in technically perfect condition in accordance
with its intended use and the instructions laid down in
the user manual.
.
WARNING
Fire hazard! Never use the product for
extracting inflammable, glowing or burning
particles or solids or liquids. Never use the
product for extracting aggressive fumes (such
as hydrochloric acid).
1. "Intended use" as laid down in EN-ISO 12100-1 is the use for
which the technical product is suited as specified by the
manufacturer, inclusive of his directions in the sales
brochure. In case of doubt it is the use which can be
deducted from the construction, the model and the function
of the technical product which is considered normal use.
Operating the machine within the limits of its intended use
also involves observing the instructions in the user manual.
0507060100/281013/B FAN-42 | SF 4200
.
WARNING
Never reach into the inlet or outlet of the fan
when the fan is not properly connected to the
ductwork.
Modifications
Modification of (parts of) the product is not allowed.
2
TECHNICAL SPECIFICATIONS
2.1
General
Net weight
Unrestricted airflow
2.2
Dimensions
See fig. 1 on page 10.
2.3
Electric system
Power
Available connection
voltages
2.4
Pressure drop
See fig. 2 on page 10.
2.5
Ambient conditions
Min. operating temperature
Nom. operating temperature
Max. operating temperature
Max. relative humidity
2.6
Sound pressure (for indication only)
Sound pressure
according to ISO 3746
3
INSTALLATION
3.1
Unpacking
Check that the product is complete. The package should
contain:
- fan
- inlet flange, incl. fixing material
- outlet bush, incl. fixing material
- flexible hose 1,5 m, Ø 200 mm
- synthetic bush Ø 160-200 mm
34 kg (75 lbs)
3
3000 m
/h (1765 CFM)
1,5 kW (2 HP)
- 230V/3ph/50Hz
- 400V/3ph/50Hz
- 208-230/460V/3ph/60Hz
(default setting: 460V)
5°C (41°F)
20°C (68°F)
45°C (113°F)
80%
72 dB(A)
EN - 4