1
PREFACE
ENGLISH
Using this manual
This manual is intended to be used as a work of
reference for professional, well trained and authorised
users to be able to safely install the product mentioned
on the cover of this document. Take your time to
carefully read and understand the manual before
mounting the CB. Always keep the manual with the
product.
The figures referred to in the text, can be found in the
back of this manual.
Pictograms and symbols
The following pictograms are used in this manual.
Suggestions and recommendations to
.
simplify carrying out tasks and actions.
CAUTION
.
Procedures, if not carried out with the
necessary caution, could damage the
product, the workshop or the environment.
2
IDENTIFICATION OF THE
PRODUCT
The identification plate (fig. 1) contains the following
data:
A product name
B serial number
C supply voltage and frequency (50/60Hz)
D power
3
SAFETY INSTRUCTIONS
The manufacturer does not accept any liability for
damage to the product or personal injury caused by
non-observance of the safety instructions in this
manual, or by negligence during installation, use,
maintenance and repair of the product mentioned on
the cover of this document.
The user of the product is always fully
responsible for observing the local safety
instructions and regulations.
•
Everyone working on or with the product, must be
familiar with the contents of this manual.
•
Never change the order of the steps to perform.
•
The product has been designed exclusively for
connecting a stationary welding fume extractor SFS
[Statiflex
400-MS], an in the extraction arm
integrated working light (WL) and/or automatic
start/stop device (AST) and an extraction fan FAN
14/28/42
[SF 1400/2400/4200]
0507200010/CB/010111/E
•
•
•
•
•
4
4.1
See fig. 2.
4.2
See the identification plate and the separately supplied
electric diagram.
4.3
5
The product has been designed especially for
connecting a stationary welding fume extractor SFS
[Statiflex
working light (WL) and/or automatic start/stop device
(AST) and an extraction fan FAN 14/28/42
2400/4200]
is used for a fixed installation- can be used for various
supply voltages and frequencies. Also the following
thermal relays (NTR) can be built in:
- NTR 1,4 - 2,0 A
- NTR 1,7 - 2,4 A
- NTR 2,2 - 3,2 A
- NTR 3,0 - 4,7 A
- NTR 4,0 - 6,3 A
- NTR 5,5 - 8,0 A
- NTR 7,5 - 10,5 A
- NTR 10,0 - 14,0 A
The product consists of the following main
components (see fig. 3):
A cover
B housing
C fuse holder
to the mains.
D glass fuse
Using the product for other purposes is considered
contrary to its intended use. The manufacturer
accepts no liability for any damage or injury
resulting from such use. The product has been built
in accordance with state-of-the-art standards and
recognised safety regulations.
Only use the product in technically perfect
condition.
Inspect the product and check it for damage.
Protect the product against water and humidity.
Never use the product in an explosive environment.
Make sure that the workshop contains sufficient
approved fire extinguishers.
TECHNICAL SPECIFICATIONS
Dimensions
Electric system
Ambient conditions
Min. operating temperature
Max. operating temperature
Max. relative humidity
GENERAL DESCRIPTION
400-MS], an in the extraction arm integrated
to the mains. The control box (CB) -which
5°C
45°C
80%
[SF 1400/
EN - 5