1 609 929 H72.book Seite 2 Dienstag, 15. März 2005 8:40 08
Before each use, check the machine. If dam-
age is detected, do not use the machine. Have
repairs performed only by a qualified techni-
cian. Never open the machine yourself.
Before each use, check the cable and plug. If
damage is detected, do not use the machine.
Have repairs performed only by a qualified
technician.
During work breaks, when not in use or when
working on the machine (e. g. changing tool in-
serts, repairs, cleaning, adjustments), pull the
mains plug.
PAS 12-27 F: Connect the machine only to
socket-outlets with earthing contact.
PAS 12-27 F: The machine may be connected
only to properly earthed mains. The socket
and extension cable must have a functional
protective conductor.
Do not drive over, crush or stretch the cable.
Danger of explosion and fire! Do not vacuum
inflammable or explosive fluids; for example,
petrol, oil, alcohol, solvents. Do not vacuum
hot or burning dust. Do not operate the ma-
chine in rooms where the danger of an explo-
sion exists.
The machine must not be used to vacuum ma-
terials that are detrimental to health. e. g., as-
bestos.
Electrostatic charging of dust and the machine
can occur occasionally.
Do not expose the machine to rain.
Children may operate the machine only under
adult supervision.
Bosch is only able to ensure perfect operation
of the machine if the original accessories in-
tended for it are used.
11 • 1 609 929 H72 • TMS • 03.03.05
Mounting
Insert the vacuum hose 6 into the hose connec-
tion piece 4 until it latches.
To remove the vacuum hose 6, press the unlock-
ing button 5 to the left and pull out the vacuum
hose.
For vacuuming, the permanent filter 3 must be
inserted.
In addition, a dust bag 13 must be used when
dry vacuuming.
When using a dust bag, the permanent filter 3 re-
mains unclogged and the vacuuming perform-
ance is maintained longer. Also, the disposal of
dust is made easier.
To insert the dust bag, slide the cardboard frame
fully onto the connection piece inside of the con-
tainer. Make sure that the dust bag completely
faces against the outline of the container 12. At-
tach the blower head.
Hook in the latches 11 and close.
Insert the extension tubes firmly into each other.
Insert the accessory holder 10 from above into
the holder on the blower head 9. Afterwards, in-
sert the angle piece into the accessory holder
from the bottom until it can be heard to latch.
For disassembly of the accessory holder 10,
press the ends of the angle piece together and
pull it out towards the bottom. Remove the acces-
sory holder to the top.
Starting Operation
Observe correct mains voltage: The voltage of
the power source must agree with the voltage
specified on the nameplate of the machine.
Equipment marked with 230 V can also be con-
nected to 220 V.
Switching On and Off
PAS 11-21/PAS 12-27:
To start the machine, set the On/Off switch 1
to I.
To switch off the machine, set the On/Off
switch 1 to 0.
PAS 12-27 F:
To start the machine, set the operating mode
switch 1 to I.
To switch off the machine, set the operating
mode switch 1 to 0.
English - 2