Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation (FCC 15.19).
Modifications not expressly approved by this company could void the user's authority to operate
this equipment (FCC section 15.21).
IMPORTANT:
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense (FCC section 15.105).
Industry Canada (IC)
Contains IC: 11019A-091732
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with radio frequency exposure limits set forth by Industry Canada for an
uncontrolled environment. This equipment should be installed and operated with minimum distance
20 cm between the device and the user or bystanders.
European Union (ETSI)
The RF Module Radio has been certified for use in the European Union countries and conforms to
the low voltage directives and safety directives.
A declaration of conformity is maintained on file as described in Annex II of the R&TTE Directive.
Conformity is indicated on the back nameplate with the "CE" marking.
FR
Emplacements dangereux
Caractéristiques
Modèle
Température
Connexions électriques
Protection contre l'infiltration
Compatibilité électromagnétique
32
FLP1 HAZARDOUS LOCATION INSTRUCTIONS
FLP1
Fonctionnement : -10 à 50 °C, médium du processus :
-10 à 50 °C, stockage : -40 à 75 °C
Connexion USB Um = 5,25 V, alimentation externe Um
= 21 V
IP67 (avec le port USB et le couvercle du port de charge
installés)
En présence d'un champ de RF ≥ 3 V/m sous toutes les
plages de pression, une réduction de performance d'un
niveau acceptable peut être constatée
P/N DGAU-0323 REV 0 8/3/2015