TEC60, TEC60LPG
➤ Insert the generator into the casing and screw it into place (fig. 5, page 4).
➤ Mount the casing flap and attach it with the pins (fig. 6, page 4).
9.3
Securing the silencer
Observe the following instructions when installing the exhaust pipe:
• Do not create any sharp bends which will inhibit the flow of exhaust fumes.
• Align the manifold (fig. 7 1, page 5) along the housing to ensure greater
damping of vibration.
• Use the exhaust pipe extension to divert the exhaust fumes (fig. 7 2, page 5).
Secure the extension to the vehicle floor (fig. 7 3, page 5).
➤ Secure the silencer (fig. 7 4, page 5) as in one of the alternatives shown in
fig. 8, page 5 to fig. b, page 6.
9.4
Installing the tank and fuel supply line (only TEC60)
Please observe the following instructions for the installation location:
• The tank bottom must be positioned at a maximum of 0.3 m below the bottom of
the generator.
• The top of the tank must not be higher than the top of the generator otherwise
the fuel will not be able to feed in.
➤ Lay the fuel line as straight as possible.
➤ Secure the tank, see fig. c, page 7 and chapter "Connecting the float (only
TEC60)" on page 26.
9.5
Installing the canister and gas supply line
(only TEC60LPG)
Please observe the following instructions for the installation location:
• The gas bottle bottom must be positioned at a maximum of 0.3 m below the
bottom of the generator.
• The top of the gas bottle must not be higher than the top of the generator.
➤ Lay the fuel line as straight as possible.
➤ Secure the gas bottle, see fig. d, page 7.
EN