Preparing The Device; Installing The Device; Electrical Connection; Supply Line - Mennekes eMobility-Gateway Manuel D'utilisation Et Guide D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51

5.5 Preparing the device

f Select openings for cable entry on the rear, top or bot-
tom side and open using an appropriate tool.
Depending on the opening used, a length of not
more than 40 cm is needed inside the device for
the electrical connection.
f Fit the supplied membrane plug in the opening pro-
vided on the enclosure.
f Route the lines through the membrane screw connec-
tion into the enclosure.

5.6 Installing the device

Fig.: 6. Device drilling dimensions [mm]
f Mark the mounting holes.
f Drill holes in the wall with the diameter required by
selected mounting material.
f Attach the device to the wall by using the supplied
dowels and screws.
f Check the device for firm and secure attachment.
f Cover the screws inside the enclosure with the supplied
plugs.
186,5
210,85

5.7 Electrical connection

5.7.1 Supply line

L
N
Fig.: 7. Connecting the supply line
f Uncover and strip the supply line.
Core
L
N
PE
f Connect the individual cores to the terminals L, N and
PE.
f Check the individual cores for proper connection and
screws for firmness of fit.
PE
Stripping length [mm]
6.5
6.5
8-10
EN
9

Publicité

Table des Matières
loading

Table des Matières