10. Settings
10.1
User settings
i
Settings which can be made by the user.
1. Press and hold the <MENU> key.
2. As soon as
5Et
appears in the left-hand display, release the <MENU> key.
"
toL
appears in the left-hand display and the current value in the right-hand display.
Function
Change of setting/value
Access to next setting, altered settings are stored
Exit from menu.
Attention: Altered setting is however stored
Setting
Tolerance for display value "0"
Display resolution
Balance weight
Unit for balance weight
Acoustic signal
Automatic start
Display resolution for rim width in
0.25 inch or 0.5 inch increments
10.2
Basic settings
i
Basic settings which can only be made following consultation with or by customer service.
1. Press and hold the <MENU> key.
2. As soon as
5Et
appears in the left-hand display, release the <MENU> key.
3. Press the <mm/inch> key within 1.5 seconds.
"
P0t
appears in the left-hand display and the current setting in the right-hand display.
Left
Right
Setting
display
display
P0t
on
Switch-on and switch-off of
oFF
electronic vernier caliper
ALU
on
Locking of electronic vernier caliper for
oFF
attachment of adhesive weights
PEd
on
Storage of balancing position in ALU and
oFF
PAX programs by way of pedal or time
r0t
on
Measurement of radial run-out
oFF
rnd
on
Special rounding-off with higher display of
oFF
weights in ounces
Sicam snc società unipersonale
Left display
Right display
toL
Current value in
grams / ounces
rE5
1 or 5
unb
6rA
oun
5nd
on
oFF
CAr
on
oFF
LAr
0.50
0.25
Settings | SBM 855 | 41
Key
<-> or <+>
<OK> or <MENU>
<STOP>
Description
Entry of balance weight value below which the value "0" is to
be displayed.
Passenger vehicle:
Standard value 4,5 g (0,25 oz), max. value 25 g (1,25 oz).
Commercial vehicle:
Standard value 45 g (1,5 oz), max. value 250 g (8 oz).
5 g / 0.25 oz - Standard resolution
1 g / 0.05 oz - Fine resolution
6rA = Display in grams
oun = Display in ounces
on = An acoustic signal sounds on storing the data
determined
oFF = No acoustic signal sounds on storing the data
determined
on = Start of measurement by closing wheel guard
oFF = Start of measurement by pressing <START> key
(with wheel guard closed)
0.50 inch
0.25 inch
Description
Setting not possible, always select oFF
Setting not possible, always select oFF
Setting not possible, always select oFF
Setting not possible, always select oFF
Setting not possible, always select oFF
en
|
656 229
2010-11-22