Refer to the diagram below for the general installation of a SmartSense with Essence
Note: The Essence wall controller is not used when SmartSense is installed. Start/Stop for the fan can be
accomplished by using a switch inline with the AC power to the fan.
10
fans
®
Junction Box
for Low Voltage
Control Wiring
Junction Box
for High Voltage
Power Wiring
Essence Fan
WWW.BIGASSSOLUTIONS.COM
Ceiling-mounted Upper
Temperature Sensor
2-conductor shielded cable
18–22 AWG Stranded
(provided by installer)
Maximum distance >1000 ft
(>305 m)
SmartSense Wall Controller
(mounting plate not shown)
© 2015 DELTA T CORP.
ALL RIGHTS RESERVED.
fans.
®
10%
FAN SPEED
100%
55°F
THRESHOLD TEMPERATURE
100°F
WINTER MODE
SUMMER MODE