Term. 3 +24 and Term. 4 – 24 The power supplies for the accessories are connected; this output is
used for the power supply of the safety devices or accessories with a Fuse F2 of 0.5 A. Rit. The
maximum power available is 0.5 A.
-
Term. N.5 is connected to the earth of the system
N.B. - The control unit is equipped with a connector for OPTIONAL connection of the CABAT, operation on
backup battery starts as soon as there is a power outage.

PROGRAMMING

Self learning of Opening-Closing stops and Automatic Closing Time
1. Press the PROG. button, the flasher will come on steady to inform you that you have entered
programming mode.
2. Place the doors in the preferred open position and press the button P/P ; door M2 will close down to the
stop, after 2 sec. door M1 will start closing down to the closing stop. Once both doors are closed, door M1
will open followed by door M2 up to the maximum opening stop (the entire process of acquisition of stop
positions is carried out in slow motion).
The first manoeuvre carried out by the control unit is a closure. This allows the installer to check whether the
two connection wires of the motor are wired correctly, if there is not a closure, perform a RESET by using the
tip of a screwdriver to touch the two Pins labelled RESET, the control unit will immediately stop operation
thus allowing inversion of the polarity of the cables if they were found to be reversed.
3. as soon as the doors reach the completely open stop position, the countdown begins for automatic
closing, once the desired time has elapsed, again press the button P/P, the gate will begin the closing
movement which sill automatically conclude the self-learning phase.
N.B. Depending on the stop point of maximum opening, automatically in normal operation the control unit
will stop the doors in advance to prevent striking the mechanical stop which MUST be installed.