instructions.
Open the packaging and take out the equip-
ment with care.
Remove the packaging material and any
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
Inspect the equipment and accessories for
transport damage.
If possible, please keep the packaging until
the end of the guarantee period.
Danger!
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or suff ocating!
Automatic Domestic Water System
Wrench for coarse filter
Original operating instructions
3. Proper use
Applications
Irrigation and watering of green areas, vege-
table beds and gardens.
Operation of lawn sprinklers.
For drawing water from ponds, streams, rain-
water butts, rainwater cisterns and springs
For supplying service water
Transport media:
For the pumping of clear water (fresh water),
rainwater or light suds/service water.
The maximum temperature of the fluid must
not exceed +35°C if the equipment is opera-
ted permanently.
Do not use the equipment to pump inflamma-
ble, gassing or explosive fluids.
The pumping of aggressive liquids (acids, al-
kalis, silo seepage etc.) as well as liquids with
abrasive substances (sand) must likewise be
avoided.
This equipment is not designed to convey
drinking water.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
Anl_PE-HWA_630_SPK7.indb 84
Anl_PE-HWA_630_SPK7.indb 84
GB
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains voltage/frequency ................ 230 V~, 50 Hz
Power consumption: ................................... 630 W
Pumping rate max. ...................................3300 l/h
Delivery head max. ...................................... 36 m
Delivery pressure max. ...........0.36 MPa (3.6 bar)
Suction height max. ....................................... 8 m
Pressure connection: ..........................................
.....................approx. 33.3 mm (R1 female thread)
Suction connection: .............................................
........................approx. 42 mm (R1¼ male thread)
Water temperature max. ............................... 35°C
Protection type: .............................................IPX4
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
As a basic principle, we recommend the use of
a preliminary filter and a suction set with suction
hose, intake cage and non-return valve, in order
to prevent long priming periods and unnecessary
damage to the pump as a result of stones and
solid foreign bodies.
5.1 Connecting the intake line
Fasten the suction hose (at least approx. 19
mm (¾") plastic hose with spiral reinforce-
ment) to the suction connection (1) approx.
42 mm (R1¼ male thread) of the equipment
either directly or via a threaded nipple.
The suction hose used should be equipped
with an intake valve. If the intake valve cannot
be used, a non-return valve should be ins-
talled in the intake line.
Position the intake line so that it rises from
the water withdrawal point to the equipment.
Avoid positioning the intake line higher than
the pump, as this would delay the escape of
air bubbles from the intake line and impede
the priming process.
Install the intake and discharge lines in such
a way that they do not exert any mechanical
pressure on the equipment.