F.F. Group BSPU 800/19 Notice Originale page 4

Pompe avec reservoir de pression jet
Masquer les pouces Voir aussi pour BSPU 800/19:

Publicité

4
| English
ENGLISH
SAFETY MEASURES
Read carefully the operating instruction
before assembling and starting. The appli-
ance must not be used by operators who
are not thoroughly acquainted with the
instructions handbook (operating instruc-
tions). Moreover, the appliance must not be
used by persons under the age of 16.
The user is liable towards third parties in the area
f
where the appliance is in operation.
Before starting it is necessary to make sure that
f
there are the necessary electrical protection mea-
sures, by means of a test carried out by a specialist.
While the pump is operating persons must
not be in the liquid to be pumped.
The pump may be connected only by means
of a safety switch for fault currents, with
a rated opening current up to 30 mA and
a socket with an earth contact installed in
compliance with the regulations.
Protection: at least 10 Amps.
Operation in swimming pools and garden
ponds is not recommended.
CAUTION: Before checking, unplug the
pump from the mains!
Replacing the connecting up line requires using
special tools and therefore this must carried out
by the manufacturer or its service engineers.
The pump may only operate with a pipe connect-
ing the appliance (extension) that is no lighter
than a rubber hose mod. H07 RNF in compliance
with the DIN 57282 or DIN 57245 standard.
The noise (continuous equivalent in dbA) of the mo-
f
tor-driven pump is less or equal (≤) to 85dbA.
The voltage (230 Volts alternating current) in-
f
dicated on the pump' s rating plate must corre-
spond to the available mains voltage.
The temperature of the liquid conveyed must not
f
exceed35°C.
Make sure that the plugged electrical connections
f
are in an area safe from flooding and are protect-
ed from humidity.
Before use it is necessary to check that the plug
f
and the mains connection line are not damaged.
Unplug from the mains before performing any
f
work on the pump.
Avoid directly exposing the pump to the jet of water.
f
The user is responsible for complying with the lo-
f
cal regulations for assembly and safety.
The user by taking appropriate measures (e.g. in-
f
stalling an alarm, reserve pump and the like) will
have to exclude the possibility of indirect damage
caused by flooding premises due to failure of the
pump.
In the event of the pump failing, repair work may
f
only be carried out by an authorized service. Only
genuine spare parts must be used.
BSPU 800/19 - BSPU 900/24 - BSPU 1300/24
It is notified that in conformity with the law on
f
product liability
We cannot be held responsible for the damage
f
caused by our appliance:
1. Because of improper repairs not carried out by
the personnel of the assistance points autho-
rized by us,
2. If GENUINE SPARE PARTS are not used to re-
place parts
3. If the indications and provisions given in the
instructions handbook are not complied with.
The same provisions hold for the accessories.
TECHNICAL DATA
Article Number
43 487
Model
800/19
V
Voltage /
Frequence
Hz
Rated Power
W
Max. height
m
Max.
L/h
flow rate
Max.suction
m
height
Max. Grain
mm
Size
Diameter of
Connecting
Pipe
Max.
bar
Pressure
Max. Noise
dB
Max.media
C
o
temperature
Cable Lenght
m
Pressure
L
tank volume
Weight
kg
Protection
Insulation
Class
USE
CAUTION: Sector of use
The pressure tanks units are used to supply
water to houses, farms and factories when
the water may be drawn from a well or from a
spring and, in addition, for irrigation in market gar-
dening or agriculture. To raise the pressure of the
water mains in accordance with local regulations
43 488
43 489
BSPU
BSPU
BSPU
900/24
1300/24
230
230
230
50
50
50
800
900
1300
38
42
50
3500
3600
4500
8
8
8
1
1
1
1"
1"
1"
1,5~
1,5~
1,5~
3,0
3,0
3,0
85
85
85
35
35
35
1
1
1
19
24
24
10,4
15,0
16,5
IPX4
IPX4
IPX4
B
B
B

Publicité

loading

Ce manuel est également adapté pour:

Bspu 900/24Bspu 1300/2443 48743 48843 489