Télécharger Imprimer la page

F.F. Group BSPU 800/19 Notice Originale page 21

Pompe avec reservoir de pression jet
Masquer les pouces Voir aussi pour BSPU 800/19:

Publicité

BSPU 800/19 - BSPU 900/24 - BSPU 1300/24
PROBLEM
Motor will not start
Pump will not suck
Pump connects
with very low water
intake
Insufficient rate
of flow
The thermal cut-out
switch cuts off the
pump
PROBLÈME
Le moteur ne
démarre pas
La pompe n'aspire
pas
Débit insuffisant
Le relais thermique
désactive la pompe
TROUBLESHOOTING
CAUSES
No mains voltage
ƒ
Pump impeller jammed
ƒ
Thermostat detached
ƒ
Suction valve not in water
ƒ
Pump chamber with no water
ƒ
Air in suction pipe
ƒ
Suction valve not airtight
ƒ
Suction rose (suction valve) clogged
ƒ
Max. suction lift exceeded
ƒ
Pressure of air cushion in the
ƒ
delivery tank too low.
Suction height too high.
ƒ
Dirty suction rose.
ƒ
Water level falls quickly.
ƒ
Pump flow rate reduced by foreign
ƒ
bodies.
Motor overloaded. Friction too
ƒ
great due to foreign bodies
RÉSOLUTION DES PROBLÈMES
CAUSES
Absence alimentation électrique
ƒ
Couronne pompe bloquée
ƒ
Thermostat débranché
ƒ
Le clapet d'aspiration n'est pas
ƒ
dans l'eau
Chambre pompe sans eau
ƒ
Air dans le tuyau d'aspiration
ƒ
Clapet d'aspiration non étanche
ƒ
Crépine obstruée
ƒ
Dépassement de la hauteur max.
ƒ
d'aspiration
Hauteur d'aspirat. trop élevée
ƒ
Crépine encrassée
ƒ
Le niveau de l'eau baisse rapid.
ƒ
Débit de la pompe réduit par des
ƒ
corps étrangers
Moteur surchargé.
ƒ
Frottement trop fort dû à des
corps étrangers.
ENGLISH
REMEDIES
Check voltage
ƒ
Dismantle the pump and clean
ƒ
Put the suction valve into water (min.
ƒ
30cm.)
Pour water into the suction union
ƒ
Check the seal of the suct. pipe.
ƒ
Clean the suction valve.
ƒ
Clean the suction rose.
ƒ
Check the suction height
ƒ
Increase the pressure of the air cushion in
ƒ
the filling valve (1.5 bar)
Check suction height.
ƒ
Clean the suction rose.
ƒ
Set the suct. valve lower down.
ƒ
Clean the pump and replace the worn parts.
ƒ
Eliminate the foreign bodies. Wait for the
ƒ
thermal cut-out switch to trigger again
(approx. 20 mins.).
FRANÇAIS
REMEDIES
Vérifier l'alimentation
ƒ
Démonter la partie hydraulique et contrôler
ƒ
si la couronne peut tourner librement, puis
remonter soigneusement
Plonger le clapet d'aspiration dans l'eau
ƒ
(30cm min.)
Verser de l'eau dans le raccord d'aspiration
ƒ
Vérifier l'étanchéité du tuyau d'aspiration
ƒ
Nettoyer le clapet d'aspiration
ƒ
Nettoyer la crépine
ƒ
Contrôler la hauteur d'aspiration
ƒ
Vérifier la hauteur d'aspiration
ƒ
Nettoyer la crépine
ƒ
Abaisser le clapet d'aspiration
ƒ
Nettoyer la pompe et remplacer les pièces
ƒ
usées
Eliminer les corps étrangers.
ƒ
Attendre que le relais thermique se
déclenche à nouveau (20 min.)
21
www.ffgroup-tools.com

Publicité

loading

Ce manuel est également adapté pour:

Bspu 900/24Bspu 1300/2443 48743 48843 489