not washable and cannot be re-
generated, and must be replaced
approximately every 4 months of
operation, or more frequently for
particularly heavy usage (W).
- The Grease filters must be
cleaned every 2 months of op-
eration, or more frequently for
particularly heavy usage, and can
be washed in a dishwasher (Z).
• Clean the hood using a damp
cloth and a neutral liquid detergent.
W
Z
Controls
Switches the lighting system on and
L Light
off.
Switches the extractor motor on and
M Motor
off.
V Speed Sets the operating speed of the
extractor:
1. Low speed, used for a continuous
and silent air change in the presence
of light cooking vapour.
2. Medium speed, suitable for most
operating conditions given the optimum
treated air flow/noise level ratio.
3. Maximum speed, used for eliminating
the highest cooking vapour emission,
including long periods.
L Light
Switches the lighting system on and off.
V Speed Sets the operating speed of the
extractor:
0. Motor Off.
1. Low speed, used for a continuous
and silent air change in the presence
of light cooking vapour.
2. Medium speed, suitable for most
operating conditions given the
optimum treated air flow/noise
level ratio.
3. Maximum speed, used for eliminating
the highest cooking vapour emission,
including long periods.
9