Current DC
Range Resolution
200μA
0,1μA
2mA
1μA
20mA
10μA
200mA
100μA
10A
10mA
Resistance Ω
Range Resolution
200Ω
0,1Ω
2kΩ
20kΩ
10Ω
200kΩ
100Ω
20MΩ
10kΩ
Diode and continuity test
Range
Display
Positive
voltage drop of
diode
Buzzer sound:
resistance is
less than
(70 ± 20) Ω
www.ohmeron.com
Accuracy
±(1,5%+3)
±(2,0%+5)
Accuracy
±(0,8%+5)
±(0,8%+3)
±(1,0%+15)
Condition
The positive DC
current is ± 1mA,
negative voltage
is ± 3V
Open voltage is
±3V
Various
Input current: 10A (max 10 sec)
Overload protection:
0,2A/250V fuse
10A unfused
Various
Overload protection
max 250V DC or AC peakvalue
Note: at 200Ω range, the
resistance of the test leads
should be deducted from the
measured value.
Various
Overload protection:
Max 250VDC or AC peak value
Warning: Do not input any vol-
tage at this range for
safety reasons.