9.1
Starting
ATTENTION
H range:
General purpose:
Chilled:
Fresh meat:
L range:
Press SET key to confirm the set value.
Now the unit is operating and does not require any further programming. The refrigerating cycle is fully automatic
according to the factory-set parameters, which can be modified by authorised personnel only.
ATTENTION
24 hours after starting check evaporator state. If ice has formed, defrost frequency should
be increased. In low temperature units the evaporator condition should be checked every
week during the first month of
10.
Wiring
A wiring diagram, specific for the units of the Solo series, is enclosed with these use and
maintenance instructions.
11.
Maintenance and repairs
Suitable maintenance is crucial for obtaining longer life, perfect working conditions and high
efficiency of the unit as well as for ensuring the safety features provided by the manufacturer.
12
Routine maintenance
Good operation of the unit requires the condenser to be cleaned periodically (frequency of
cleaning depends on the environment where the unit is installed).
Turn off the unit and clean it by blowing air from the inside outwards. Should no air jet be
available, use a long-haired brush and work on the outside of the condenser.
In case of water-cooled condensers have the unit cleaned by a plumber with special descaling
agents.
- front cover is secured correctly
Before starting the unit act as follows:
Connect the unit to the mains. The display is turned on and shows OFF.
-
If the unit has a preheating cycle, leave it in this condition for at least 3 hours.
-
If the unit has a voltage monitor, leave it in this condition for at least 7 minutes to
-
have the counting phase carried out
Set the required cold room temperature.
-
-
Press ON/OFF key to switch the unit on.
min temp. –5°C max. temp. +10°C
recommended temperature: +3°C
recommended temperature: +1°C
recommended temperature: -2°C
min temp. –25°C max. temp. -15°C rec. temp -21°C
Setting room temperature:
•
Connect the unit to the mains. OFF is displayed.
•
Press SET for three seconds. The green led lights up and the previously set
temperature is displayed.
•
To change this value press following keys:
•
UP to increase temperature
•
DOWN to decrease temperature
operation.