Connection For Fine Atomizers - Weka HC 10 D Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Anleitung HC 10_D_mehrp
GB

Connection for fine atomizers

(thermal)
When using a thermal evaporator (all bioactive
sauna heaters), Nhum has to be connected to N
oven and Lhum to WB (water bath) in the oven.
Important! The terminal WM (water shortage) is not
assigned!
Connection for fine atomizers
When using an electronic fine atomizer (AV 50),
Nhum has to be connected to N and L1hum to L1
from the transformer of the finer atomizer.
Note: For an exact description please see the
installation and operating instructions of the fine
atomizer.
Operation and functions
Description of the operating elements
5
No.1 Operating switch
No.2 Control factor regulator
No.3 Operating status indicator
No.4 Button for temporary operation
10
27.08.1956 10:30 Uhr
Operating display indicators
LED
color
Green
Red
No indication
Important:
For safety reasons, the controller switches off
operation after a period of 6 hours. Resetting is only
possible with the operating switch.
To activate the humidity controller you have to turn
the switch to „ON". The required humidity can be set
from 10 - 100% with the rotary regulator.
Note: The actual humidity in the cabin depends on
the size and density of the sauna cabin and therefore
has to be determined by experiment.
Fast-select button
This function serves to prevent oversaturation with
scented essences and salt solutions during a sauna
session. To get full enjoyment from scented
essences and salt solutions we recommend
activating the short-run button „K" before entering the
sauna (approx. 15 minutes ON time).
Scented atomization
The HC 10 D can be used together with the AV 50 or
AV 10 to atomize scents and fragrances in controlled
mode. To stimulate a good sense of smell it is
important not to use scents and fragrances all the
time (this will only lead to insensitivity) but to observe
fixed periods of non-use. The atomizing periods can
be set with the „H" button to suit the scent or
fragrance in question.
For details of the optimum period of use, please see
the description issued for the scent or fragrance in
question.
Important!
Use only those fragrances, scented essences
and salt solutions stipulated by the
manufacturer.
Important safety information:
Mis-use may harm your health!
Be sure to observe the doses stipulated!
Seite 10
Indicator
Function
lights up
X
Control system ready
X
Evaporator working
6 hours safety cut-out

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

500.0603.20.0437.469.32

Table des Matières