Sound level in cabinet is too
high.
The cabinet does not operate
at all. Cooling or interior light
does not operate. No indicator
lamps light.
Not enough carbon dioxide in
the water
Too much carbon dioxide in
the water
No carbon dioxide.
Water flow very low
17
The refrigerating system will always produce
some sounds. A pulsing sound is heard when
coolant is pumped inside the cooling pipes.
A ticking sound from the thermostat can be
heard when the compressor switches on and
off. The sound level varies depending on the
operation of the cabinet.
If you feel the sound level is incorrect:
Make sure the pipes at the back of the
cabinet do not touch each other. Carefully
bend them if they do.
If the cushion spacers (between the cabinet
wall and pipes) come loose, put them back in
place again.
Carefully follow the instructions in the chapter
"Installing the cabinet".
Power does not reach the cabinet. (Try
connecting another electrical device to the
power outlet.)
The cabinet is not switched on.
The fuse has blown.
The power plug is not properly connected.
Incoming water pressure too low.
The carbon dioxide is running out. Replace
the gas cylinder.
Dilute with ordinary water. (See the section
"The water dispenser functions")
The gas cylinder is empty. Replace the gas
cylinder.
Drain off a large amount of carbonated water
(about 1 litre)
Incoming water pressure too low.
Remove and clean the strainer in the
connecting valve.
Sediment in the water. Replace the filter or
install a pre-filter.