LEGEND
1 – Push botton back-lighted (Red/Blu)
2 – Red led
3 – Plastic cover
4 – Thermostat knob
5 – Mechanical switch (optional)
6 – External Class II sensor
COLLEGAMENTO ALLA RESISTENZA
With the front of the thermostat in the required position,
1)
connect the mains cables (phase: brown–neutral: blue) and the
yellow-green earth wire through the faston (presents only Class
I version). Insulate the connectors with the specially provided
insulating boots.
Push joined connection cable back into the housing of the
2)
controller and push onto the base of the heating element.
Align the electronic control and WARNING: Do not twist
3)
the electronic control more than 30°C in either directions.
Press housing against the base of the heating element in order
4)
to compress the o-ring, and hand-tighten grub screw (tightening
torque approx. 0,5Nnm)
Connect the mains cable to the electricity supply.
5)
33