N.B.: It is recommended to use an external thermostat with OFF-SET of at least 3° if wanting to use COMFORT CLIMA
(Climate).

Setting the pellet-air mix

Setting the pellet-air mix makes it possible to adjust smoke extraction and
the quantity of loaded pellet in a simple manner. This makes it possible
to adjust combustion according to stove draught and pellet hardness. To
turn on adjustment press the P6 and P7 keys simultaneously, the following
strings will appear on the display:
PELLET
- 3
TIRAGGIO
NB: the number indicated during parameter modification only refers to a percentage valve that acts on the default
parameters set in the electronic board (exclusively during the work phase). These values must be changed in case of
improper combustion due to, in many cases, purchasing a pellet that is different from that used during stove initial testing.
! IMPORTANT

Automatically loading the auger

In order to automatically load the auger (when the stove is new the loading auger is empty), complete these operations:
1. Cut and then restore power to the thermo-stove using the main switch located on the back.
2. The display will show FINAL CLEANING and then OFF
3. Keep the P4 button pressed for 2 seconds the wording MENU SET OROLOGIO (Set clock menu) appears
4. Press the P4 key 4 times: the screen will show MENU STATO STUFA (Stove state menu)
2000
150°
COCLEA 0
STATO 0
THE AUGER IS STOPPED
2000
150°
COCLEA 1
STATO 0
AUGER ACTIVATED
! IMPORTANT
9.7. Canalisation management
The air flow in the canalisation is adjusted using the P5 button. Press the key for a few seconds and the following screen will appear:
CANALISATION SPEED. The speeds range from 1 to 5 and A Use the P5 and P4 keys to adjust the speed of the motor used to blow
into the canalisation.
|
|
|
VELOCITA
|
|
CANALIZ-
|
GOOD 10 C- GOOD 12 C
Use and maintenance manual
2
THIS FUNCTION IS ONLY EFFECTIVE IS DURING STOVE TESTING THE PROPER
ADJUSTMENTS HAVE BEEN MADE.
AFTER LOADING THE AUGER, IT IS RECOMMENDED TO EMPTY THE BRAZIER INTO THE TANK
BEFORE START-UP.
CANALISATION FAN
1
Using the P6 and P7 keys modifies the draught value, using the P5
and P4 keys it is possible to dose the amount of pellet used (the value
indicated during modification only shows a percentage value that acts on
the default parameters set in the electronic board).
PRESS THE P1 KEY TO ACTIVATE THE AUGER
Repeat the operation multiple times until you see pellet fall in the
brazier.
It is only possible to complete this operation if the stove is in
PULIZIA FINALE (Final cleaning) or SPENTO (OFF) state!!!
9.7.1 Canalisation fan
By keeping the P6 key pressed, it regulates canalisation fan.
Rev.0 01/03/2019
Page 56
0
PELLET
0
TIRAGGIO
EN