Climate Comfort; Room Temperature Set Modification; Mode With Supplied Room Temperature Probe; External Thermostat Mode - Efiamma GOOD 10 C Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66

Climate comfort

To access this function, press P6 and P4 keys simultaneously.
When room temperature is reached, the electronic board reduces pellet consumption to a minimum by activating the modulation, after
this the stove verifies if this temperature is maintained for a pre-established amount of time, if this happens, it automatically goes in
ECO STOP mode (the stove shuts off).
OFF
COMFORT
CLIMA
COMFORT
CLIMA
P - 2
10:30 21°
LAVORO
MODULA
P - 2
10:34 21°
ECO
STOP
N.B.:Stove operation in COMFORT CLIMA (climate) mode may start the start-up and shut-down phase multiple times throughout the
day; this may compromise duration of the resistance used for automatic stove start-up.
! IMPORTANT

Room temperature set modification

The operational modes of the stove with thermostat activated are divided into 2 types:
- with supplied room probe (not available on insert models) positioned on the back of the stove.
- with external thermostat (not supplied).

MODE WITH SUPPLIED ROOM TEMPERATURE PROBE

If the supplied room temperature probe is used, the display will show room temperature.
In order to set the desired temperature (room temperature set modification): press the P3 key to enter the specific menu and adjust
the desired value using P5 and P4 keys. Once reached, the screen will display the wording LAVORO MODULA (Modulate Work), in this
case the stove will reduce pellet consumption to a minimum, decreasing the heating power.

EXTERNAL THERMOSTAT MODE

If an external thermostat correctly connected to the board is used as shown on the electrical diagram, the screen no longer shows room
temperature but the wording T ON (WHEN THE CONTACT IS CLOSED) , or T OFF (WHEN THE CONTACT IS OPEN).
NB: IN ORDER TO ENABLE THE EXTERNAL THERMOSTAT, USE THE P3 KEY AND THE PRESS P1 MULTIPLE TIMES TO REACH
THE VALUE "EST" ON THE SCREEN; CONFIRM BY PRESSING THE P6 KEY.
Room temperature will be adjusted directly from the thermostat installed on the wall. Once the temperature set on the thermostat is
reached, the remote control display will show the wording LAVORO MODULA (Modulate Work), in this case the stove reduces pellet
consumption to a minimum, decreasing the heating power to a minimum. If the COMFORT CLIMA (Climate) mode is active, the stove
carries out the shut-down and automatic re-start phase (for details see paragraph 9.3).
N.PEL.
N.H2O
GOOD 10 C- GOOD 12 C
Use and maintenance manual
USING THIS MODE IT IS NECESSARY TO MAKE SURE THAT AFTER EACH AUTOMATIC
START-UP THE BRAZIER ALWAYS REMAINS CLEAN IN ORDER TO GUARANTEE A CORRECT
AUTOMATIC START-UP.
THERMOSTAT CONNECTED.
N.ROOM
THERM.
-TC1+
Red
Blue
Black
Black
To activate Comfort Clima (Climate), press the P5 key, setting a value
different from OFF.
The set value ( in this case
function.
OPERATION:
The value regulates stove re-start temperature. EXAMPLE:
• room temperature set at 21°C
• comfort clima (climate) value set at
With this regulation, the stove shuts off once 21°C is reached and re-
starts when room temperature is 18°C (21°C - 2 - 0.5 of tolerance =
approximately 18°C ). The following strings will appear in sequence on
the screen:
The modulation phase is activated since the room set temperature
has been reached. f the temperature is maintained for approximately 4
minutes the stove shuts off.
The shut-off phase is terminated, the screen will display the wording
ECO STOP. The stove remains in this state until the temperature falls
below 18°C, only then will the start-up phase be restarted.
THE COMFORT CLIMA MODE ALSO WORKS WITH AN EXTERNAL
1
2
3
4
Page 55
2°C
) activated the Comfort Clima (Climate)
2° C
N.ROOM
THERM.
-TC1+
5
6
7
8
9
10
ROOM
THERMOSTAT
SMOKE SEN-
PROBE
EXTERNAL
SOR
Rev.0 01/03/2019
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Good 12 c

Table des Matières