The plus cable of the controller unit must
include a main fuse and a switch.
Use a smaller fuse if applicable, appropri-
ate for the total maximum current of the 3
wiper motors.
Use connecting wires with a sufficiently
large diameter. See the connection dia-
gram for the recommended minimum wire
diameter. Connect the current to the cable
spades provided (ø 5 mm).
Wiper motors
Use only wiper motors of the same
type; wiper motors must be equip-
ped with an automatic park setting.
The wiper motors used must have 2
speeds to be able to use both low and
high speeds. For example, VETUS type
RWS and HDMC. VETUS type ORW is not
suitable.
Connect the wiper motors to the controller
unit as indicated in the diagram. Use con-
necting wires with a sufficiently large dia-
meter. (See the connection diagram on p.
28 for the recommended wire diameter).
Panel
Connect the control panel to the control
unit as described in the diagram. The
connector wires should have a core cross
section that corresponds to the core cross
section as indicated.
Windscreen wiper controller
Washer
A water pump or magnetic valve can be
connected to the WASHER connection for
a washer.
The current for which the water
pump or magnetic valve are sui-
table must correspond to the
onboard current (12 or 24 V).
Rain sensors
Consult the manual provided with the rain
sensors to determine how to install them.
Safeguards
Each wiper motor is individually protected
by a fuse. The washer pump is also pro-
tected by a fuse.
These fuses are under the lid of the con-
troller unit (see diagram below on how to
remove lid).
See 'Technical data' for fuse values.