The Machine; Basic Components; Controls And Control System; Function Selector Keyboard - Wow WAC 2200 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42

THE MACHINE

BASIC COMPONENTS

Refer to Figures 5, 6, 7 and 8.
a) Control consoles
h) Wheels
m) Used oil tank
bi) Oil scale
e) Drying filters
r) Heating resistance
i) Main switch
k) Fuse
f) Vacuum pump
z) tracer container

CONTROLS AND CONTROL SYSTEM

Refer to Figure 9.
A1) High pressure gauge
A3) Keyboard
A5) LCD: 4 lines, 20 characters

FUNCTION SELECTOR KEYBOARD

STOP: Press to interrupt the operation being performed in the case of the principal functions:
recovery - oil discharge - vacuum/oil reintegration - charging). Press START to resume
operation from the point of interruption. Pressing STOP during an alarm state, error state, or
end-of-operation silences the audible alarm.
RESET: Press to interrupt the operation being performed. The procedure may be restarted
from the beginning.
ENTER: Press to confirm the procedure or operation flashing on the LCD.
: Press to move downward from one procedure or operation to another within a menu.
: Press to move upward from one procedure or operation to another within a menu.
START: Press to launch the procedure or operation shown on the display.

ALARMS

HIGH PRESSURE ALARM: Beeper advise when the pressure of the fluid in the circuit reaches
20 bar. The recovery operation is automatically interrupted.
FULL BOTTLE ALARM: Beeper advise when the bottle is filled to more than 80% of maximum
capacity; that is, 18 kg. The RECOVERY operation is automatically interrupted (to cancel this
alarm, charge one or more A/C systems before recovering any more refrigerant).
EMPTY BOTTLE ALARM: Beeper advise when the quantity of refrigerant fluid contained in the
bottle is low.
SERVICE ALARM: Beeper advise whenever the total recovered refrigerant amounts to 100 kg.
To deactivate the alarm, replace the filters and the vacuum pump oil. A code for canceling the
alarm is supplied with the spare filters.
INSTRUCTIONS MANUAL
b) Taps
l) High/Low Pressure threaded connectors
n) New oil container
d) Bottle
o) Electronic scale
ps) Serial port
j) Socket for electrical supply plug
u) USB port
v) purge valve
A2) Low pressure gauge
A4) Bottle pressure gauge
A6) Printer
pag.14 - 12/11/2015

Publicité

Table des Matières
loading

Table des Matières