3.INSTALLATION AND CONNECTION

3.2 Swimming Pool Heat Pump Location

The unit will perform well in any outdoor location provided that the following three factors are
present:
1. Fresh Air - 2. Electricity - 3. Pool water filtration piping
The unit may be installed virtually anywhere outdoors. For indoor pools please consult the
supplier. Unlike a gas heater, it has no draft or pilot light problem if installed in a windy area.
DO NOT place the unit in an enclosed area with a limited air volume, where the units
discharge air will be re-circulated. There must be a lot of air circulation around the unit.
DO NOT place the unit near shrubs which can block air inlet. These locations deny the unit
of a continuous source of fresh air which reduces it efficiency and may prevent adequate
heat delivery.
Air outlet
3.3 How Close To Your Pool?
Normally, the pool heat pump is installed with in 7.5 metres of the pool. The longer the
distance from the pool, the greater the heat loss from the piping. For the most part ,the piping
is buried. Therefore, the heat loss is minimal for runs of up to15 meters(15 meters to and from
the pump = 30 meters total), unless the ground is wet or the water table is high. A very rough
estimate of heat loss per 30 meters is 0.6 kW-hour,(2000BTU) for every 5
temperature between the pool water and the ground surrounding the pipe, which translates to
about 3% to 5% increase in run time.