Module for fireplaces with hot water production for sanitary and heating purpose.
KIT-1 is a module in order to manage heating installations fed by a fireplace or an alternative source for the production of sanitary hot water
for domestic heating and SHW installations.
SHW production is a priority and it works automatically through a flow detector.
TECHNICAL SPECIFICATIONS
Dimensions
Length 402mm. Height 190mm. Depth 250mm.
Electrical specifications
Power supply 230Vac. Frequency 50Hz. Power input 80W.
Hydraulic connections
Heating chimney fitting G 3/4" – 1
Installation fitting G 3/4"
Sanitary fitting G 1/2"
REGULATIONS AND DIRECTIVES
Accordance to regulations:
EN 60730-1 AND LATER UPGRADES
EN 60730-2-9
Accordance to directive:
E.M.C. 2004/108/CE E.B.T: 2006/95/CE
INSTALLATIONS AND CONNECTIONS
Security advice
Before connecting the module to the electrical network, please, verify that the network tension is disconnected and has a value of
230Va.c.
A pressure reducer or a safety valve must be installed in order to avoid that the pressure inside the circuit is higher than 6 bars.
Connect the hydraulic installation following the indications in the schema and design of the drawing.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS