stands for the first function that applies to
cycle 1 .
Figure 6
Press "PROG" again to pass on to "F2", and
so on to the last function, "Ci".
Press "PROG" once more to exit the
programming mode and save the changes.
WARNING: if a potential drop should
occur during a programming session,
changes will not be saved and it will be
necessary to repeat the programming
procedure from the beginning.
When a cycle is underway, the "PROG" key
causes the machine to pause and does not
give access the programming mode.
The PROG key so stops the cycle at whatever
stage except the spinning step.
The DISPLAYS will then read "PAUSE"
and the machine will stay like this until the
"START" key is pressed and the cycle is
resumed.
Figure 7
Attention!
-)This function is available only when a
cycle is in progress.
-)Pauses cause heating to go off too, which
means that long stops will cause the
temperature to drop.
PROGRAMMING
Options F1, F2, F3, F4, F5, F6 and Ci can be
enabled singly and cycle by cycle. Functions
stay enabled permanently until the user
chooses to disable them.
The programming mode can be accessed
only with the door closed and with NON
coin-operated machines.
During programming, the cycle display reads
the selected cycle (1...9), whereas the time
display reads "Fy", where y is the option at
issue.
The temperature display shows the current
selection (0 = disabled, 1 = enabled; for F2
see specific description).
A cycle is selected by pressing the SEL key,
whereas options are selected through the
PROG key and enabled or disabled through
the "+" and "-" keys respectively.
When the PROG key is pushed repeatedly,
options are shown in a cyclic sequence from
F1 to Ci and then back to the current selection.
When the SEL key is pushed repeatedly,
stored cycles appear (minimum 1, maximum
9).
IMPORTANT !!!
When an option is selected for a cycle that
does not envisage it (see description of each
option) the machine will accept the selection
but the corresponding function will not be
carried out.
DESCRIPTION OF PROGRAMMABLE
FUNCTIONS
Cool-down (F1)
As a rule at the end of a high-temperature
wash cycle (above 60°C) soft water is taken
in in order for drum inside temperature to
decrease gradually. When F1 is set to 1, this
action is not performed.
Value
Function
0
Normal (default)
1
NO cool-down
This function can be programmed cycle by
cycle.
Change spinning (F2)
Final spinning can be changed from 1 minute
up to 8 minutes. This function modifies the
length of final spinning. If the setting assigned
to this function is 9, spinning will totally be
eliminated. Effective spinning means the
maximum high-speed time. The speeding
up is not affected by this function.
Value
Function
0
Normal (default)
1
1 minute spinning
2
2 minute spinning
3
3 minute spinning
4
4 minute spinning
5
5 minute spinning
6
6 minute spinning
7
7 minute spinning
8
8 minute spinning
9
no spinning
This function can be programmed cycle by
cycle.
No prewash (F3)
When this function is enabled the prewash
step is excluded.
Value
Function
0
Normal (default)
1
No prewash
This function can be programmed cycle by
cycle.
Cycle deferred start (F4)
Postpones the start of a wash cycle and
19
determines cycle delay.
If the value assigned to this function is other
than zero, as soon as the programming session
is exited the time DISPLAY will blink the
hours and the temperature will blink the
minutes whereas the cycle display will read
the selected wash cycle.
To start the countdown, just press the START
push-button: the displays will be lit
continuously.
As soon as the countdown, is over the cycle
will start automatically and the displays will
resume their usual functions.
Before the START push-button is pressed
and during the count-down all keys are
enabled.
IMPORTANT !!!
Time is displayed in the "HH.MM"format.
H stands for hours and M for tens of minutes.
Unit: hours and minutes
h
h
Range:
00
00'...23
50'
(00.00...23.50)
Resolution:
10 minutes
(0.1)
Default:
00
h
00'
Details:
When pressed, the START key excites the
CYCLE relay and the door is automatically
locked.
If the door is not closed correctly, the "door"
alarm will warn the user. If the door fails to
be locked, alarm "E6" will appear.
In this case the machine will not work until
the problem is solved and the START is
pressed once again.
If a deferred start is aborted - by entering the
programming mode and setting F4 to 00.00
- the door will be automatically unlocked.
Enable/Disable buzzer (F5)
This function enables/disables the buzzer,
which can be completely eliminated from all
cycles except for alarm sounds.
Value
Function
0
Normal (default)
1
No buzzer
Changes to this function will affect all cycles.
Changing heating temperature (F6)
This function lowers maintain temperature
by 10°C.
If a wash temperature in a cycle is normally
90°C, it can be set to 80°C by altering this
function.
Value
Function
0
Normal (default)
1
Temperature decrease
by 10°C.
Changes to this function will affect all cycles.
Enable cycles (Ci)
Stored cycles can be enabled/disabled singly,
i.e. using the SEL push-button, they can be
included/discarded from the list of those that
can be selected.