SPECIFICATIONS
PARAMETERS
ELECTRICAL:
Normal input (solar cell array voltage)
Max. input solar cell array voltage
Peak charging current:
Current Consumption when connected 12V Array
(Battery not present)
Current Consumption when connected 12V battery
(Array not present)
CHARGING CHARACTERISTICS
Max. Bulk charging current
Constant voltage for Lead-acid battery
Float mode voltage
LCD METER DISPLAY: (60031 only)
Min. LCD Display Voltage
Max. LCD Display Voltage
PROTECTION:
Over temperature protection starting at (Stop charging)
Over temperature protection reset at (Restart Charging)
MECHANICAL
Controller Dimension
Controller overall Height
Net weight
ENVIRONMENTAL CHARACTERISTIC:
Operation temperature
Storage temperature
Operation humidity range
MONITORING
LED Indicator
The 3 LEDs indicate charging status. These functions are described below.
Solar Power Indication (POWER LED - red)
ON:
Indicates solar panel properly connected and solar power supplied normally.
OFF:
No power available or insufficient voltage to active charge controller.
Charging status
CHARGING LED - blue;
"Float/Maintaining" CHARGE COMPLETE LED - green
Status
Charging
Bulk
Charge
Technical Specifications
LED
Charge Complete
"Float/Maintaining"
ON
OFF
UNITS
Volt
Volt
Amps
mA
mA
Amps
Volt
14.4 +/-0.4
Volt
13.5+/-0.4
Volt
6.0 +/-0.4
Volt
19.0 +/-0.4
ºC/°F
>85/>185
ºC/°F
<65/<149
mm
125 (L) x 65(W)
mm
Approx. 27
g
Approx. 300
ºC/°F
-5 to 50 / 23 to 122
ºC/°F
-10 to70 / 14 to 158
0 to 80% RH
Conditions
Indicates the battery is charging,
power from the solar array passes
unrestricted through to the battery.
DATA
17~22
23
12
55 max.
10 max.
10