CONTROLLER DIMENSIONS
60031 Shown
FEATURES
• Digital Meter (60031 only) –
• Protect and Maintain battery –
• Safety circuit protection –
• Reverse leakage protection – Protect batteries from discharge by solar panel
• Temperature Protection–
• Status Lights –
• Mounting Options –
INSTALLATION
The solar controller is designed to be panel mounted or wall mounted.
Installation
Panel Mounted - The charge controller may be mounted flush with the wall.
•
Flush mounting requires a rectangular cutout in the mounting surface with sufficient space (2-3
inches) behind to accommodate the controller and wiring.
Wall Mounted - The charge controller may also be mounted to the wall without making a
•
cutout. The controller will be raised from the wall; this is the quickest and easiest
mounting procedure.
Recommended Battery Capacity: 12V 35AH minimum.
CONNECTION PROCEDURES (refer to Connection diagram)
• Connect the solar panel positive side to the solar controller ARRAY + (this is marked by a
"+" tag) using a suitable wire (Be careful DO NOT short circuit the solar array.)
• Connect the solar panel negative side to the solar controller ARRAY – (this is marked by a
"-" tag) with a suitable wire.
• Connect the battery positive side to the solar controller BATTERY positive side (this is
indicated by a red collar) with either the provided "O" rings or a suitable wire (you may
strip the "O" rings from the wire without voiding your warranty).
• Connect the battery negative side to the solar controller BATTERY NEGATIVE – with a
suitable wire.
Battery voltage is shown digitally.
Protect batteries from overcharging and maintains
batteries in fully charged state.
Reverse polarity protection
Over temperature protection and auto-resume
Easy reading LED indicators.
Panel mounting / wall mounting.