Télécharger Imprimer la page

Federal Signal Corporation EMS Escape Instructions D'installation Et D'entretien page 7

Publicité

Les langues disponibles

Les langues disponibles

f.
Install the new lamp into the bracket and
secure in position with the spacer.
g.
Install the halogen reflector on the
bracket assembly using the previously retained keps nuts.
6.
EMSAL Halogen Bulb Replacement and Angle
Adjustment (see figure 11).
a.
Halogen Bulb Replacement.
A serious injury may result if lamp is touched
when hot. Always allow lamp to cool before
removing. Halogen lamps are pressurized
and if broken can result in flying glass.
Always wear gloves and eye protection when
handling the lamps.
CAUTION
Service life of lamp will be shortened if glass
portion is touched. If glass has been handled, clean
carefully with a grease solvent.
(1). Disconnect ALL power to the unit
before any maintenance is performed.
(2). Remove and retain the lamp retaining
ring, lens and o-ring.
(3). Remove the halogen lamp by pulling it
straight away.
This device is designed to use a 35-watt
(maximum) halogen lamp. Use of higher
wattage lamps can result in damage to the
lens, property damage, or serious injury to
you or others. Always use a 35-watt halogen
lamp.
(4). Install the new halogen lamp in the
socket assembly.
(5). Place the o-ring, and lens over the
halogen bulb and secure with the previously removed
retaining ring.
b.
Angle Adjustment.
The EMSAL is adjustable from plus 45
degrees to minus 45 degrees in 15 degree increments.
(1). Disconnect ALL power to the unit
before any adjustment is performed.
(2). Remove and retain the #6 x 5/16 Long
Torx head adjustment screw and lockwasher.
(3). Rotate the unit to the desired angle
and line up the swivel bracket to the nearest hole in the
mounting bracket.
(4). Insert the previously retained #6 x 5/
16 long Torx head adjustment screw and lockwasher
WARNING
WARNING
through the mounting bracket hole and securely tighten to
the swivel bracket assembly.
7.
Solaris/Barracuda LED Replacement.
A serious injury may result if LED is touched
when hot. Always allow LED to cool before
removing.
To replace the LED module in the 9-button
Solaris, see figure 12 and perform steps a through f below.
To replace the LED module in the 3-front Barracuda, see
figue 13 and perform steps a through f below. To replace the
LED module in the 3-side Barracuda, see figure 14 and
perform steps a through f below.
a.
Disconnect all power to the unit before
performing any maintenance.
b.
Remove and retain the four mounting
screws (two for the 3-side Barracuda) that secure the
bracket to the EMS Escape extrusion.
c.
Disconnect the wiring connector from the
LED module assembly.
d.
Insert the connector into the replacement
module.
e.
Secure the new LED module in position
using the previously removed screws.
f.
Reconnect all power connections and test
for proper operation.
D. Service.
The Federal factory will service your equipment or
provide technical assistance with any problems that cannot
be handled locally.
Any units returned to Federal Signal for service,
inspection, or repair must be accompanied by Return
Material Authorization. This R.M.A. can be obtained from a
local Distributor or Manufacturer's Representative.
At this time a brief explanation of the service
requested, or the nature of the malfunction, should be
provided.
Address all communications and shipments to:
Federal Signal Corporation
Emergency Products Division
Service Department
2645 Federal Signal Drive
University Park, IL 60466-3195
E. Common Replacement Parts.
Description
Lamp, Rotator
Strobe/Reflector Assy.
Lamp, Scene Light
Lamp, Halogen Flasher
Lamp, Alley
Solaris 9-button
Cuda TriOptic Front
Cuda TriOptic Side
-6-
WARNING
Part No.
8107141A
8575364A
8575107A
8107152A
8107231-03
8003105
8003059
8003057

Publicité

loading

Produits Connexes pour Federal Signal Corporation EMS Escape

Ce manuel est également adapté pour:

Quick track