EN
4.5 Programming by pilot wire (option)
Your Acova appliance can be regulated by a 6-command programming unit.
Oscilloscopes
Commands received
Ref./Neutral
No current
Alternation
* no current: 4'57''
* phase 230 V: 3''
Alternation
* no current: 4'53''
* phase 230 V: 7''
Complete alternation 230 V
Negative semi-alternance
-115 V
Positive semi-alternation
+115 V
NOTE:
You can use the «freeze protection» command on your Acova appliance's elec-
tronic thermostat for load-shedding (option available with some programming
units). When using the programming function, it is vital to use appliances of equi-
valent technology to ensure optimum levels of comfort.
IMPORTANT Boost function is in programmed mode:
When the device is controlled by pilot wire, the boost operation functions of the
radiator have priority over all programming commands, with the exception of the
stop heating (or load-shedding) command triggered by the power station.
52
Mode
Results obtained
obtained
The temperature obtained is
Comfort
that of the thermostat setting.
The temperature obtained is
Comfort
that of the thermostat setting
-1°C
- 1°C.
The temperature obtained is
Comfort
that of the thermostat setting
-2°C
- 2°C.
Eco
Economy temperature.
Freeze protection
Freeze
temperature of approx 7°C.
protection
Can be used for load-shedding.
Heating
Immediate stopping of
stop
appliance.
40017784
4.6 Open window detection activation / deactivation
Your appliance can detect a significant fall in temperature such as that pro-
duced by leaving a window open for a prolonged period in winter. It automatically
adjusts its operation to save energy.
The open / closed
window detection function
is activated on your
device by default.
SETTING THE DETECTION:
Press on the
button
10 seconds
when your
appliance is
shut down.
Press on the
button
(quick press)
to turn the
function off
or on.
On indicator
Functioning indicator
❷
(Leaving)
❹
Red
Open window detection
function activated
Flashing red
Green
Open window detection
function deactivated
07/2018
The room temperature
is measured near the
appliance.
The on
indicator
❷
for
❸
flashes red
quickly.
The
indicator
❹
changes
❸
color de-
pending on
the function
status.
Press the
button
Functioning
❸
indicator
(Arrival)
Deactivate open window
Green
detection function
Activate the open window
Red
detection function
EN
❹
53