M-system FD 96 Mode D'emploi page 216

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

A)
GAS CONNECTION
NL
Cat:
The gases used for the operation of
cooking appliances may be grouped by
their characteristics into two types:
G25
The fitting (fig. 9.2) is made up of:
A -
Gas train terminal fitting (rh or lh)
B -
Gasket
C -
Conical connector
B)
GAS CONNECTION
ES
Cat:
The gases used for the operation of
cooking appliances may be grouped by
their characteristics into two types:
G20
The fitting (fig. 9.3) is made up of:
A -
Gas train terminal fitting (rh or lh)
B -
Gasket
D -
Hose connector
A
B
C
1/2" gaz conique
216
II
2L 3B/P
G30 / G31
II
2H3+
G30 / G31
for G30 / G31
NL
Abb. 9.2
Use rigid or flexible connection pipes
which comply with applicable regula-
tions.
If compression fittings are used, tighten
firmly using two spanners (fig. 9.5b).
In particular, make sure that:
– the flexible hose does not come into
contact with any parts of the cooker
with surface temperatures in excess
of 70˚C;
– the flexible hose does not exceed 75 cm
in length and does not come into con-
tact with sharp edges or corners;
– the hose is not under tension or twist-
ed and is not kinked or too tightly
bent;
– the connection with rigid metal pipes
should not cause stresses to the gas
ramp.
– we advise replacing the gasket on the
slightest sign of deformation or imper-
fection.
– the hose can easily be inspected
along its entire length to check its
condition; hoses should replaced
after a maximum of three years.
– the cylinder cock or the supply cock
immediately ahead of the appliance is
closed whenever the cooker is not in
use.
A
B
D
ES
Fig. 9.3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mfd 96

Table des Matières