Velleman DVM760 Notice D'emploi page 6

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
DC CURRENT
Make sure to cut the power of the circuit to be measured before connecting the test leads.
• Insert the black test lead into the COM jack and the red test lead into the A jack for a maximum of 2A. For a
maximum of 20A, insert the red test lead into the 20A jack.
• Set the selector at the A or mA range.
• Connect the test leads in series with the item to be measured.
• Read the value from the LCD.
Note:
• Select a higher range when the meter shows "1".
• Respect the maximum allowed currents for each jack (2A for 2A jack, 20A for 20A jack) to avoid damages.
AC CURRENT
Make sure to cut the power of the circuit to be measured before connecting the test leads.
• Insert the black test lead into the COM jack and the red test lead into the A jack for a maximum of 2A. For a
maximum of 20A, insert the red test lead into the 20A jack.
• Set the selector at the A or mA range.
• Connect the test leads in series with the item to be measured.
• Read the value from the LCD.
Note:
• Select a higher range when the meter shows "1".
• Respect the maximum allowed currents for each jack (2A for 2A jack, 20A for 20A jack) to avoid damages.
RESISTANCE
Remove all power and fully discharge all the capacitors prior to measuring in-circuit resistance.
• Insert the black test lead into the COM jack and the red test lead into the V/ jack.
• Set the selector at the
• Connect the test leads with the item to be measured.
• Read the value from the LCD.
Note:
• Select a higher range when the meter shows "1" in the manual range mode.
• The meter may take a few seconds before showing a stable value with resistances over 1M .
CAPACITANCE
• Insert the black test lead into the COM jack and the red test lead into the Cx/hFE jack.
• Set the selector at the desired nF, 2µF or 200µF range. The range can also be selected automatically (AUTO).
• Connect the test leads with the item to be measured.
• Read the value from the LCD.
DVM760
range.
Fully discharge all the capacitors prior to measuring capacitance.
WARNING
WARNING
WARNING
WARNING
6
VELLEMAN

Publicité

Table des Matières
loading

Table des Matières