6.5 Scope of delivery
Included in the scope of delivery
Item number
Designation
Item 1
Entire C10 circulation pump
Item 1.1
3 kW heating element with mains cable
Item 1.2
Stainless steel flow pipe
Item 1.3
Domestic hot water circulation pump with mains cable
Item 1.4
Control unit with mains cable
Item 1.5
DN25 pump screw connection
Item 2
3/8" quick exhaust valve
Item 3
1" check valve for water supply
Item 4
6-bar overpressure safety valve
Operating instructions
Optional accessories
Item 5
DN25 G 1" flow indicator with float
Item 6
DN25 thermometer connection with 1 ¼" union
Required on site
Item 7
Shut-off valve for circulation pump
Item 8
Shut-off valve for bypass pipe
Item 9
Shut-off valve for supply pipe
Item 10
Drain valve for circulation pump
Item 11
Water filter (optional)
Item 12
Drain valve for ring pipe
Item 13
Insulation
Item 14
Chew protection
Item 15
Fuse box
6.6 Integration into the pipe system
On the customer side, the C10 circulation pump must be installed in a ring line according to the installation diagram in 6.4:
1. Screw the circulation pump (item 1) into the ring pipe.
2. Install the shut-off valve (item 7) before and after the circulation pump. The shut-off valve is used to disconnect the unit from the ring pipe for
maintenance.
3. Fit the shut-off valve (item 8) for the bypass pipe. The bypass pipe is used to ensure the water supply in the event of maintenance.
4. Fit the shut-off valve (item 9) for the supply pipe.
5. The supplied non-return valve (item 3) must be installed before the return of the ring pipe into the supply pipe. A second non-return valve can
also be installed at the end of the return pipe.
6. Fit the drain valve (item 10). This is used to drain the heating circuit before the shut-off valve (item 7).
7. The supplied overpressure safety valve (item 4) must be installed in the ring pipe so that the drain opening leads into an open drain. Observe
the flow direction of the valve.
8. The supplied automatic quick exhaust valve (item 2) must be installed at the highest point of the entire pipe system in a vertical position.
Make sure that the valve is installed in an area that is permanently protected from frost.
9. Install the Kerbl drinking bowl with ring pipe connection. For drinking bowls with a connection only from above or below, the branch pipe
must also be equipped with pipe trace heating.
10. In areas of the pipe system that are at risk of frost and draughts, additional pipe trace heating must be installed.
11. Supply and return pipes must be additionally provided with pipe insulation (item 1). Attached pipe trace heatings and pipe insulations must
be equipped with chew protection (item 13).
Number
1x
1x
1x
1x
1x
2x
2x
1x
1x
1x
Art. No.
223131
223132
Art. No.
221975