Electrical Connections; General Information - Fulgor Milano F6RT24 Serie Instructions D'installation

Masquer les pouces Voir aussi pour F6RT24 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DANGER
Disconnect power before servicing the product.
Failure to do so could result in death or
electrical shock.

General information

x The models may be powered at 240V or
208V.
This cooktop does not require a neutral connection. If
the cooktop is to be completely enclosed in a cabinet,
feed the cooktop cable through the opening in the
cabinet. Make the electrical connection following the
appropriate steps for your installation.
Your cooktop must be connected to the proper
electrical voltage and frequency as specified in the
table on the right.
Figure 12. Location of serial tag
Connect with copper wire only
If the house has aluminum wiring, follow the
procedure below:
1. Connect the aluminum wiring to the copper wire
by using special connectors designed and
Underwriters Laboratories-listed for joining copper
to aluminum. Follow the electrical connector
manufacturer's recommended procedure.
2. Aluminum/copper connection must conform with
local codes and industry- accepted wiring
practices.

Electrical Connections

WARNING
The flexible conduit (supplied) 3 feet long (100 cm)
located at the right rear of the cooktop bottom box
should be connected directly to junction box. Do not
cut the conduit. A U.L - or CSA - listed conduit
connector must be provided at each end of the power
supply cable (at the cooktop and at the junction box.)
A time delay fuse or circuit breaker is recommended.
Do not ground to a gas pipe. Do not have a fuse in the
grounding or neutral circuit.
Fuse both supply (phase) lines.
WARNING
Improper connection of aluminum house wiring to
the copper leads can result in a serious problem.
Model
240 V 60 Hz
F6RT24**
24"
5,2kW
30"
F6RT30**
7,1kW
F6RT36**
36"
9,9kW
National Fire Protection Association
Batter/march Park Quincy, Massachusetts 02269
A three-wire, single phase, 240 Volt 60 cycle electrical
system (properly circuit protected to meet Local
Codes of NFPA No.70) must be provided. Unit must
be properly grounded in accordance with local wiring
code. The chart below recommends the minimum
circuit protector and wire size if the appliance is the
only unit on the circuit. If smaller sizes of wire are
used, the unit efficiency will be reduced and a fire
hazard may be created. It is advisable that the
electrical wiring and hookup be accomplished by a
competent electrician.
This touch control works using optical light sensing
WHFKQRORJ\ :KHQ ¿UVW FRQQHFWLQJ HOHFWULFDOO\ RU
after a power failure, any direct strong light over the
sensor area may affect the touch control functionality.
When powering on the unit make sure that no strong
light is shining direct over the touch control zone,
it can compromise the start-up sensor calibration
resulting in an unresponsive touch control.
Installation Manual
ENGLISH
Power Supply
Approval
208 V 60 Hz
21,7A
3,90kW
18,8A
512Y30IR
29,6A
5,33kW
25,6A
41,3A
7,43kW
35,8A
512V50ID
WARNING
code
512T40II