INSTALLATION AND FUNCTIONING OF THE DEVICE
1) Do not install and do not try to repair the product if it was damaged during transport.
2) Do not connect the power cord to the power supply, unless specifi cally required.
3) In order to ensure the correct working of the device in safe conditions, it is absolutely forbidden to expose
the product to atmospheric agents and to direct heat sources (Fig. 1). The temperature of the installation
environment has to be between 5 °C and 38 °C (41 °F – 100 °F).
4) The appliance must be installed in a ventilated area.
5) To allow proper evacuation of hot air, install the product at the following distances:
Minimum distance from walls
Air output side
Air input sides
6) Prepare the water tubes as follows:
6.1) If necessary, insert cable-tie-wrap (Ref. P3 Fig. 6).
6.2) Insert the joint ( Ref. P4 Fig. 6) in the tube, and bring cable-tie-wrap on the joint ( Ref P5 Fig. 6).
6.3) Fasten the joint clockwise (Ref. P7 Fig. 7), direct it as needed and tighten it.
6.4) When connecting the pipes, make sure that the pipe from the pump (not supplied) and/or the fi lter assembly
(not supplied with the unit) is connected in the position indicated with IN (Ref. P8 Fig. 7), and that the return
pipe is connected to the hydroponic system in the position indicated with OUT (Ref. P9 Fig. 7).
7) Install the unit in the chosen place allowing the visibility of the equipment.
8) Start the pump, make sure that the water fl ows regularly in the circuit and that there are no leaks. In the case
of anomalies or leakage in the hydraulic circuit, review the connections.
9)
CAUTION: Make sure that the water that reaches the device is fi ltered.
10) Make sure that the power supply requirements match those shown on the technical plate, visible on the back
of the unit (Ref. A3 Fig. 4).
11) When the pump is functioning, connect the cable power supply to the power socket with the plug (Ref. A5
Fig. 4). Then, the display will show OFF.
Pressing the power button (Ref. A7 Fig. 8) for at least 3 seconds, your device will start working, on the dis-
play it is indicated the actual water temperature. To display the temperature to be reached press the SET
button (Ref.A8 Fig. 8) to return to the water temperature press the SET button (Ref.A8 Fig. 8) or wait for 5
seconds.
12)
CAUTION: A 2-minutes delay was added to prevent compressor failure at the fi rst start.
13) To stop the device, press the power button (Ref. A7 Fig. 8) for at least 3 seconds, the display will show OFF.
CAUTION: The appliance must be installed at a height below the water level.
CAUTION: To prevent damages, the unit cannot operate without water fl ow (pump off ).
10
L
E
R
50 mm – 1,97 in
60 mm – 2,36 in
Tab. 5-1
L
I
N
E
EN