N.B. In this case the power which can be taken from each of the
two outputs is half the rated nominal power.
- Ensure that the sum of the loads to be supplied does
not exceed the nominal power of the electric generator.
- Magnetothermic protective devices or similar should
be placed between the generator and electrical
equipment, according to the tables shown below.
- To make both parallel and serial connections, use the
special bridges provided in the accessories to the
electric generator on the terminal board fig. 15 ref. 1.
Single voltage distribution
Hz
50
V
115
W.
1700
A
14.8
Hz
50
V
115
TAB 1
W.
2700
A
23.5
Hz
50
V
115
W.
4000
A
34.8
N.B: In these cases just one magnetothermic device should be
installed, see fig. 16/17.
Double voltage distribution
IS 2500
Hz
50
V
115/230
W
1700
A
7.4
Hz
60
V
120/240
W
1900
A
7.9
N.B: In these cases two magnetothermic devices should be
installed, see fig. 18/19, dimensioned on the current values (A)
shown in Table. 2.
4.4.

Generator - Mains switching

A switch should be placed on the line to switch the user
appliances from the generator to an external power line.
The switch should be dimensioned according to the size
of the loads: a general diagram is shown in fig. 20.
IS 2500
60
50
60
120
230
240
1900
1700
1900
15.8
7.4
7.9
IS 3500
60
50
120
230
2900
2700
24.2
11.7
IS 4500/IS 5500
60
50
60
120
230
240
4800
4000
4800
40
17.4
IS 4500/IS 5500
IS 3500
50
50
115/230
115/230
2700
4000
11.7
17.4
60
60
120/240
120/240
2900
4800
12.1
20
GB
60
240
2900
12.1
20
GENERATORS
-
-
17