Installation
Using the mobile communication module
If the alarm panel is already in operation, put the panel into installation
mode. This ensures that opening the housing will now not trigger a
sabotage alarm.
Note
Open the housing of the alarm panel.
1.
Disconnect the alarm panel from the power supply. To do this, disconnect both
2
the external power supply (unit / 230 V connection) and the backup batteries.
Only for FUAA50xxx: Carefully remove the ribbon cable which connects the key
panel/touch panel and the motherboard.
Lead the antenna cable from the outside through the cable openings in the
3
back panel into the inside of the housing. Secure the antenna outside the
housing.
Connect the mobile antenna to the mobile communication module (see figure).
4
Insert the SIM card into the card holder of the mobile communication module
5
(see figure).
The PIN code of the SIM card must be switched off or set to "0000".
Equip the mobile communication module with the supplied plastic holders. Now
6
carefully place the mobile communication module on the plug connectors of the
motherboard and press down firmly. Ensure that the pins do not get bent. (See
figure)
Only for FUAA50xxx: Now reconnect the key panel/touch panel to the
7
motherboard.
Reconnect the power to the alarm panel, and reattach the (backup) battery.
Reconnect the (backup) battery and reconnect the alarm panel to the mains
supply.
29