Par.
Description
6.01
SPEED V1
6.02
SPEED V2
6.03
SPEED V3
Par.
Description
7.01
DIGITAL INPUT 1
7.02
SPEED IN 1
7.03
DIGITAL INPUT 2
7.04
SPEED IN 2
7.05
OUTPUT 1
7.06
SCHEDULE PROGRAMME 1
7.07
START TIME PROGRAMME 1
7.08
STOP TIME PROGRAMME 1
7.09
OUTPUT 2
6. FIXED SPEED
VALUES
Units.
Default
Min.
rpm
950
700
rpm
1400
700
rpm
2800
700
7. INPUTS OUTPUTS
VALUES
Units.
Default
Min.
Unused
External stop
Unused
External stop INV
Fixed speed
Fixed speed INV
rpm
1400
700
Same as parameter 7.01 but for input 2.
Same as parameter 7.02 but for input 2.
OFF
Salt chlorinator
Wash
Alarm (NO)
OFF
Alarm (NA)
Run
Clock (NO)
Clock (NA)
OFF
M-Su
OFF
M-F
S-Su
M, T,X,T,F,S,Su
00:00
00:00
Same as parameter 7.05 for output 2.
28
Max.
2800
Set the speed at which the pump is to run at speed V1.
2800
Set the speed at which the pump is to run at speed V2.
2800
Set the speed at which the pump is to run at speed V3.
Max.
An input can be used to perform a remote stop (the
INV option is for a contact that opens to switch on)
or for the pump to operate at a certain speed when
the input 1 is activated or deactivated (INV option).
If digital input 1 is enabled for fixed speed, indicate
2800
the speed at which it is to operate when this input
is given.
Relay 1 can be programed to be activated (or
deactivated for NC-terminated options) whenever the
pump is started, when the pump is filtering (saline
chlorinator), when an alarm occurs or when a certain
programming cycle is running.
This parameter is visible only if one of the 2 clock
options is selected in the previous parameter.
It enables the days or the block of days to be
programmed, such as M-Su that refers to Monday
through Sunday, in which the relay is to be activated.
Indicate start time for programme 1.
Indicate start time for programme 2.
EN